Parameterisation Connection; Led Display; Software Installation - IFM Electronic efector 190 Data Matrix Notice Pour Utilisateurs

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parameterisation connection

Connect the USB adapter cable E2D100 to the parameterisation connection of the
sensor. Ensure for connection of the M8 connector that the coupling nut is tightly
screwed into the internal thread of the sensor socket.
Connect the USB connector of the adapter cable E2D100 with your PC only
after installation of the software!

LED display

LED no.
Colour
Type of indication
1
LED green
Permanently lit
2
LED yellow
Permanently lit
3
LED yellow
Permanently lit
4
LED red
Permanently lit

Software installation

Insert the CD with the dualis Control Panel operating program (E2D102) into your CD
drive. If the installation does not start automatically, use the following commands to
start it manually:
• Select the
Run...
• Activate the
Browse...
in the selection window.
• Open the setup.exe file and confirm the selection by
Installation will be started.
Follow the instructions of the installation program.
After successful installation connect the USB connector of the adapter cable E2D100
to your PC.
This will start automatic hardware recognition of your operating system. Follow the
instructions of the hardware assistant and during the query for the process of the dri-
ver selection select the option
Function
Flashing
Operating voltage applied - sensor parameters not yet set
a data set is loaded - sensor's parameters set and ready
Communication with the PC is active (USB connection exists
and
Connect sensor
Data Matrix code successfully read - corresponding protocol
data sent
Error message: Data Matrix code not detected
command in the start menu. A dialogue window will open.
button and change to the English directory on the CD ROM
Browse...
menu item executed)
.
OK
searching for the driver of the unit.
. Then
33