Installation

4
Installation
4.1

Mechanical connection

Use only original accessories, in case of doubt consult the manufacturer.
Take care that the carrying capacity / working load limit (WLL) of the lifting device/carrier is not exceeded,
through the load of the device, the optional attaching devices (turning device, fork sleeves, crane boom
etc.) and the additional load of the gripping goods!
Gripping devices always have to be gimballed, so they can swing freely in any position.
In no case it is allowed to mount gripping devices with lifting devices/carriers in a rigid way!
Break of the suspension may occur within short time. Death, severe injuries and material damage can
result!
When using the device on optional attachments (such as fork sleeves, crane boom, etc.), it cannot be
excluded, due to the lowest possible construction of the total device (to avoid loss of lifting height), that
the device may collide with adjacent components if the device is suspended in an oscillating motion and
unfavourable positioning during travel movements of the carrier device. This should be avoided as far as
possible by positioning the device appropriately and in a sensible driving style. Damage resulting from this
will not be regulated within the scope of the warranty.
The rotator with load is hindered from
swinging freely and hangs diagonally
downwards when the load is lifted.
Risk of breakage!
4.1.1

Standard flange plate

The device is attached to the lifting equipment/carrier with a standard flange plate or a custom made flange
plate connection.
Attaching the device to the lifting equipment/carrier take care that all local safety regulations are observed.
56100057
The rotator with load can swing freely in any direction and
hangs vertically downwards when the load is lifted.