Type 2030, 2031, 2031 K, 2032,
2033, 2037
TechnicalData
Medium temperature for body:
Body material
Stainless steel
PVC (see PT-graph)
PVDF (see PT-graph)
PP (see PT-graph)
Tab. 2:
Medium temperature for body
Medium temperature for diaphragms:
Material
temperature
EPDM / PTFE -10 ... +130 °C Steam sterilization up to +150 °C
FKM
-5 ... +130 °C
Tab. 3:
Medium temperature for diaphragms
6.3.2 maximum permitted medium pressure
Permitted medium pressure depending on the medium temperature.
DN 65 - 100
10
8
6
4
2
temperature [°c]:
Fig. 3:
Graph of medium pressure / Medium temperature
All manuals and user guides at all-guides.com
temperature
-10 ... +140 °C
-10 ... +60 °C
-10 ... +120 °C
-10 ... +80 °C
remarks
Dry up to +150 °C
Otherwise only briefly up to +150 °C
PVDF
PP
PVC
20 40 60 80 100 120 140
Maximum permitted medium pressure for control function a
The values apply to body made of:
• Plastic,
• VA forged steel and VA precision casting, VA block material as well
as VA tube-formed body with socket, DIN welding neck flange and
welded connection in accordance with EN ISO 1127 (ISO 4200).
orifice
actuator
Max. sealed medium pressure [bar]
(diaphragm
size ø
pressure on one
size)
[mm]
dn [mm]
EpdM/
65
175
175
80
225
100
225
Tab. 4:
Maximum permitted medium pressure CFA
english
pressure on both
side
sides
ptfE
EpdM/
fkM
fkM
8.0
5.0
5.0
5.0
4.5
2.5
10.0
10.0
6.0
8.0
4.0
3.5
ptfE
4.5
2.0
4.5
1.5
9