4.8
Installation procedure
The stove installation procedure depends on the type of water system it is connected to. It can also differ
depending on the use of an external thermostat or the internal probe.
For the correct electrical and water connections, contact a specialised technician.
4.9
Idle period (end of season)
If the stove is not used for long periods, and/or at the end of each season, it is advisable to proceed as follows
- remove all the pellets from the hopper;
- disconnect the power and remove the power cable;
- clean thoroughly and, if necessary, have any damaged parts replaced by qualified personnel;
- protect the stove from dust with suitable covering;
- store in a dry and safe place protected from atmospheric agents.
5 STOVE CLEANING
Stove cleaning is very important to prevent: blackening of the glass, poor combustion, deposits of ash and unburnt
products in the brazier, reduced thermal efficiency.
The stove must only operate with the fire door closed.
The fire door seals must be checked periodically to prevent any air from entering; the combustion chamber and
pellet duct work in a negative pressure and the fume exhaust in a positive pressure.
Routine cleaning is normally carried out by the customer following the instructions in the manual, whereas
extraordinary maintenance, at least once a year, must be performed by the authorised Service Centre.
- Cleaning operations for all parts must be carried out with the stove unplugged and
cold;
- Dispose of cleaning waste in accordance with the current local regulations;
- The stove must not be operated without its cladding;
- Avoid the creation of smoke and unburnt products during lighting and/or normal operation.
Given below are the control and/or maintenance operations for correct stove use and operation.
Parts / Period
Type of cleaning
Brazier
Ash compartment-pan
Door glass
Heating chamber tube bundle
Manifold – fume extractor
Glass - door seal
Pipe - flue connection
Cleaning the brazier
5.1
Remove the brazier and the ash deposited in the combustion chamber and brazier holder. A suitable vacuum
cleaner may be used for this purpose. This operation must be carried out daily, especially in case of accumulated
unburnt matter, to ensure perfect combustion conditions, since the brazier holes allow the flow of combustion air.
Brazier dirty
1 day
2-3 days
routine
cleaning
■
Brazier clean
Brazier Holder clean
1 month
routine
routine
cleaning
cleaning
■
■
■
45
battery tray
lever
1 year
2-3 months
extraordinary
routine
cleaning: carried out
cleaning
by the Service Centre
■
The brazier must rest on the
brazier holder and precisely on
the entire ring band without air
gaps.
TERMO-PERLA
■
■
■
■