To connect the heating stove to a DHW system it is advisable to contact a competent technician in order to best
optimise the plumbing connections and the performance of the entire system without compromising stove operation.
For the connection to the DHW circuit it is necessary to install a monostable 3-way valve outside the stove whereas
the circuit is not functional with the DHW pump.
During stove transport the gaskets in the plumbing system may come loose and/or break, causing water leaks during normal
operation; therefore make sure to check the tightness of the circulating pump and heating chamber connection rings and vent
the residual air during water filling and after the first hours of operation.
Hydraulic diagram - heating pellet stove ref. COLA 10-14kW 06-2010
Heating pellet stove
Pellet heating
chamber – 2010
Pt=10-14 kW
Int. volume 18.5 l.
KEY
Drain cock
Pressure sensor / Pressure gauge
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Non-return valve
Thermostat
T > 85°C
Circuit / heating chamber air ven
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor
Valves to be included in system during
installation – not supplied with the unit
39
Heating DELIVERY
male 3/4"
OVERPRESSURE WATER
DISCHARGE F1/2"
Heating RETURN
male
3/4"
Water supply F1/2 "
Pmax 2 bar
Arrangement
PLUMBING CONNECTIONS on back of stove