Install the Baffles for an Upper Side-Wall Exhaust Vent

Make sure that all horizontal baffles are the full
!
CAUTION
width of the inside of the enclosure and are in the
correct location. If the baffles are not the full width
of the enclosure or incorrectly located, poor cooling
performance can result.
If the enclosure depth is 24 inches or more and less than 26 inches (See
Art01806):
- Install a wood, aluminum or galvanized steel top baffle [13] between the
top of the refrigerator and the top of the upper exhaust vent [24].
- Make sure that the top baffle is less than 1/4 inch [15] from the top of
the refrigerator and baffle overlaps the refrigerator 1 inch or less.
- Make sure that the baffle is against the wall of the vehicle at the top
of the upper exhaust vent and less than 1/4 inch above the opening
for the upper exhaust vent.
- Install an aluminum or galvanized steel bent-sheet condenser baffle [26].
- Make sure that the bend of the condenser baffle is the full width of
the inside of the enclosure.
- Make sure that the bend of the condenser baffle is flush with the
bottom edge of the door frame of the upper side-wall exhaust vent.
- Make sure that the top edge of the condenser baffle is 1/4 inch or
less [15] from the lower rear corner of the condenser.
If the enclosure depth is 26 inches or more (See Art01807):
- Install a wood, aluminum or galvanized steel top baffle [13]
between the top of the refrigerator and the top of the upper
exhaust vent [24].
- Make sure that the top baffle is less than 1/4 inch [15] from
the top of the refrigerator and that the baffle overlaps the
refrigerator 1 inch or less.
- Make sure that the baffle is against the wall of the vehicle at
the top of the upper exhaust vent and less than 1/4 inch [15]
above the opening for the upper exhaust vent.
- Install a solid box baffle [21] between the lower intake vent and the
upper exhaust vent.
- Make the solid box baffle either from wood or from an
aluminum or galvanized-steel sheet.
- Make sure that the bottom of the solid box baffle is 18 inches
to 18 1/2 inches above the bottom of the enclosure [17] (4 1/4
inches to 4 3/4 inches above the top of the lower intake vent
opening REF) [18].
- Make sure that the back of the solid box baffle is
perpendicular to the bottom of the enclosure.