12 Device Information
1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread
of heating water
3.3
Heat output / COP
3.4
Sound power level device / outdoors
3.5
Sound pressure level at a distance of 1 m (indoors)
3.6
Heating water flow
with an internal pressure differential of
3.7
Air flow rate
with an external static pressure differential of
3.8
Refrigerant / total filling weight
3.9
Lubricant; total filling weight (R404A)
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Air duct inlet and outlet (min. internal dimensions)
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
5.4
Nominal current A2 W35 / cos
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Controller internal/external
1. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters,
such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following
meaning: 2 °C external air temperature and 55 °C heating water flow temperature.
2. See CE declaration of conformity
3. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
All manuals and user guides at all-guides.com
°C / °C
°C
at A2 / W35
1
at A-7 / W35
kW / ---
1
at A2 / W35
kW / ---
1
at A-7 / W75
kW / ---
1
at A7 / W35
kW / ---
1
at A10 / W35
kW / ---
dB(A)
dB(A)
m³/h / Pa
m³/h / Pa
m³/h / Pa
type / kg
type / litres (R404A)
type / litres (R134a)
H x W x L cm
Inch
L x W cm
kg
V / A
1
A2 W35
kW
A
A / ---
3
452160.66.15 · FD 9310
LIH 26TE
IP21
Indoors
Up to 75 / above 18
-25 to +35
8.4
13.0 / 2.8
12.9 / 2.6
15.9 / 3.2
15.7 / 3.0
18.1 / 1.8
18.0 / 1.7
19.8 / 3.8
19.5 / 3.6
20.4 / 3.9
20.2 / 3.7
62 / 68
58
1.8 / 3700
2.7 / 8200
9000 / 0
8000 / 25
R404A / 3.7
R134a / 3.1
Polyolester / 1.9
Polyolester / 1.77
171 x 75 x 103
G 1 1/4" external
72.5 x 72.5
389
400 / 25 T
5.0
30
9.0 / 0.8
9.3 / 0.8
2
Automatic
Reverse cycle
Yes (heated)
Yes
2
Internal
LIH 26TE
5.0
5.16
EN-10