LAW 9IMR - LAW 14ITR
13 Device information
1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location
2.5
Performance level
3
Operating limits
3.1
Heating water flow / return
3.2
Cooling water flow
3.3
Air (heating)
3.4
Air (cooling)
4
Flow / sound
4.1
Heating water flow / internal pressure differential
in accordance with EN 14511
free compression
Minimum heating water flow
internal pressure differential
free compression
4.2
Noise-power level in accordance
1
with EN 12102 outdoors
4.3
Sound pressure level in 10 m distance outdoors
4.4
Noise-power level in accordance
with EN 12102 indoors
4.5
Sound pressure level in 1 m distance indoors
4.6
Air flow
5
Dimensions, weight and filling quantities
3
5.1
Device dimensions
5.2
Weight of the transportable unit(s)
incl. packaging internal / external
5.3
Device connections for heating
5.4
Refrigerant / total filling weight
5.5
GWP value / CO
equivalent
2
5.6
Lubricant / total filling quantity
5.7
Volume of heating water in the outdoor component
5.8
Buffer tank
Nominal volume
Permissible operating temperature
Max. operating overpressure
Electrical pipe heater
Immersion heater (optional)
5.9
Domestic hot water cylinder
Usable capacity
Heat exchanger area
Permissible operating temperature
Max. operating pressure
Immersion heater
5.10 Start-to-leak pressure, safety valve
6
Electrical connection
6.1
Supply voltage / fuse protection
www.gdts.one
°C
°C
°C
°C
m³/h / Pa
m³/h / Pa
dB(A)
1 2
dB(A)
dB(A)
dB(A)
m³/h / Pa
internal
H x W x D mm
external
H x W x D mm
kg
inches
type/kg
--- / t
type/litres
Litres
in litres
in litres
bar
Compressor
Heating cartridge
Compressor +
heating cartridge
RCD-Type
452162.66.04 · FD 9912
LAW 9IMR
Air
Split reversible
WPM Econ5Plus inte-
WPM Econ5Plus inte-
grated
No
Indoors / outdoors
Indoors / outdoors
Variable
up to 55 / from 20
up to 55 / from 20
7 to 25
-20 to +30
+10 to +43
1,6 / 20000
Pa
38800
0,75 / 8500
Pa
68500
63
35
42
35
3600
1920 x 740 x 950
1920 x 740 x 950
834 x 950 x 330
1380 x 950 x 330
215 / 69
G 1 1/4"
R410A / 1.9
2088 / 4
Polyvinyl ether
(PVE) / 0.9
0
100
°C
85
bar
3,0
kW
4
2, 4 or 6
kW
up to 6
277
m²
3,15
°C
95
bar
10,0
kW
1,5
2,5
1~/N/PE 230 V
(50 Hz) / C25 A
1~/N/PE 230 V
(50 Hz) / C35 A
3~/N/PE 400 V
(50 Hz) / C25 A
B
LAW 14IMR
LAW 14ITR
Air
Air
Split reversible
Split reversible
WPM Econ5Plus inte-
grated
grated
No
No
Indoors / outdoors
Variable
Variable
up to 55 / from 20
7 to 25
7 to 25
-20 to +30
-20 to +30
+10 to +43
+10 to +43
2,4 / 30400
2,4 / 30400
29600
29600
0,9 / 10000
0,9 / 10000
77300
77300
68
67
40
39
42
42
35
35
7200
7200
1920 x 740 x 950
1380 x 950 x 330
222 / 94
222 / 116
G 1 1/4"
G 1 1/4"
R410A / 2.38
R410A / 2.98
2088 / 5
2088 / 6
Polyvinyl ether
Polyvinyl ether
(PVE) / 1.3
(PVE) / 1.3
0
0
100
100
85
85
3,0
3,0
4
2, 4 or 6
2, 4 or 6
up to 6
up to 6
277
277
3,15
3,15
95
95
10,0
10,0
1,5
1,5
2,5
2,5
1~/N/PE 230 V
(50 Hz) / C40 A
1~/N/PE 230 V
(50 Hz) / C32 A
3~/N/PE 400 V
(50 Hz) / C32 A
B
B
English
4
EN-19