12 Device Information

Device information for brine-to-water heat pumps for heating purposes
1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Cooling, flow
Brine (heat source, heating)
Brine (heat sink, cooling)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water
(flow/return flow)
3.3
Heat output / COP
3.4
Cooling capacity / COP
3.5
Sound power level
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
3.7
Brine throughput with an internal pressure differential
(heat source) of
3.8
Refrigerant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.
www.dimplex.de
All manuals and user guides at all-guides.com
°C
°C
°C
°C
at B0 / W35
K
1
at B-5 / W55
kW / ---
1
at B0 / W50
kW / ---
1
at B0 / W35
kW / ---
at B20 / W8
kW / ---
at B20 / W18
kW / ---
at B10 / W8
kW / ---
at B10 / W18
kW / ---
dB(A)
m³/h / Pa
type / kg
2
H x W x L mm
Inch
Inch
kg
V / A
1
B0 W35
kW
A
A / ---
4
SI 5USR
SI 7USR
SI 9USR SI 11USR SI 14USR
Reversible
Reversible
Reversible
IP20
IP20
IP20
Indoors
Indoors
Indoors
Up to 55
Up to 55
Up to 55
+8 to +20
+8 to +20
+8 to +20
-5 to +25
-5 to +25
-5 to +25
+5 to +25
+5 to +25
+5 to +25
Monoethyl-
Monoethyl-
Monoethyl-
ene glycol
ene glycol
ene glycol
25%
25%
25%
9.9
9.9
10.4
4.1 / 1.8
5.6 / 1.9
7.4 / 2.0
4.9 / 2.8
6.4 / 2.7
8.7 / 2.7
5.2 / 4.0
6.9 / 4.0
9.1 / 4.0
5.4 / 4.6
7.0 / 4.5
9.9 / 4.6
6.6 / 5.3
8.6 / 5.3
12.0 / 5.4
5.4 / 5.6
7.0 / 5.5
9.9 / 5.6
6.8 / 6.7
8.8 / 6.6
12.4 / 6.7
54
55
56
0.45 / 1900
0.6 / 3300
0.75 / 2300
1.2 / 16000
1.7 / 29500
2.3 / 25000
R407C / 0.9
R407C / 0.9 R407C / 1.25 R407C / 1.6
800 × 600 ×
800 × 600 ×
800 × 600 ×
450
450
450
G 1¼" exter-
G 1¼" exter-
G 1¼" exter-
nal
nal
nal
G 1¼" exter-
G 1¼" exter-
G 1¼" exter-
nal
nal
nal
101
104
110
400 / 16
400 / 16
400 / 16
1.3
1.67
2.21
22 (without
30 (without
15
SS)
SS)
2.35 / 0.8
3.0 / 0.8
4.0 / 0.8
3
3
3
Yes
Yes
Yes
1
1
1
Internal
Internal
Internal
12
Reversible
Reversible
IP20
IP20
Indoors
Indoors
Up to 55
Up to 55
+8 to +20
+8 to +20
-5 to +25
-5 to +25
+5 to +25
+5 to +25
Monoethyl-
Monoethyl-
ene glycol
ene glycol
25%
25%
9.9
9.4
9.8 / 2.1
12.2 / 2.3
11.3 / 2.9
13.5 / 2.9
11.6 / 4.1
13.7 / 4.0
11.4 / 4.6
14.1 / 5.0
14.1 / 5.3
17.4 / 5.9
11.6 / 5.7
14.7 / 6.4
14.1 / 6.5
17.4 / 7.1
56
56
1.0 / 4100
1.3 / 4850
3.0 / 24000
3.5 / 17900
R407C / 2.1
800 × 600 ×
800 × 600 ×
450
450
G 1¼" exter-
G 1¼" exter-
nal
nal
G 1¼" exter-
G 1¼" exter-
nal
nal
114
126
400 / 16
400 / 16
2.6
3.41
26
26
4.7 / 0.8
6.15
3
3
Yes
Yes
1
1
Internal
Internal
E-7