5. INSTALL HOOD
5.1 Run power cable to installation location. Position the hood in its intended location. Using a pen, mark the position
of the screws (smaller part of the keyholes, see pictures below for the 5 keyholes locations). Remove the hood.
5.2 Install 4 no. 8 x 1/2'' screws, leaving a 1⁄8'' gap (do not install the no. 5 screw yet).
HD0403
5.3 Attach the wire clamp, insert the power cable in the hood. Place the hood under the cabinet, slide it in position and
tighten the wire clamp to secure the cable. Make sure the adapter/damper assembly enters the duct opening.
Tighten the 4 screws completely, then add the last screw (screw no. 5) in the center keyhole. Make sure the
damper flap opens freely.
6. CONNECT WIRING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
Connect cable into wiring box using provided wire connectors.
Connect wires as follows: BLACK to BLACK, WHITE to WHITE
and GREEN or BARE wire under GREEN ground screw. DO
NOT FORGET TO CONNECT THE GROUND.
1
2
WARNING
!
- 10 -
3
5
4
HE0059
G
S
ROUND
CREW