7. WIRING INSTALLATION

Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions
are not completely understood, or if there is any doubt as to whether the appliance is properly grounded. Do not
use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the
appliance, in accordance with all applicable codes and standards. Turn off electrical power at service entrance
before wiring.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current. This appliance is
equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
Position the outlet within the space covered by the decorative flue. Place the outlet at a maximum
distance of 24" (from where the cord exits from the hood). The center of the outlet must be
positioned at 3½" from the center of the future hood location (as illustrated beside). Make sure this
does not interfere with a mounting bracket fastening area or with the decorative flue (where the
flue touches the wall).

8. INSTALL HOOD MOUNTING BRACKET

!
When cutting or drilling into wall, do not damage electrical
wiring and other hidden utilities.
Construct wood wall framing that is even with the surface of wall studs.
Wood wall framing must be at least 1/2" thick and 3" high. Fasten wood wall
framing to wall studs for a solid installation.
Make sure that the height of the framing will allow the mounting bracket to
be secured to the framing within the dimensions shown.
After wall surface is finished, carefully center and level the hood
mounting bracket over installation location. Secure it to wall framing using
3 no. 8 x 1½" screws.
Using a level, draw a vertical line up to the ceiling starting from the
mounting bracket center.

9. INSTALL UPPER FLUE MOUNTING BRACKET

Center the upper flue mounting bracket with the center line previously
drawn in step 8 and place it flush with the ceiling.
Use the upper flue mounting bracket as a template to mark the position of
its screws.
Drill the 3 screw holes using a 3/16" drill bit.
Insert the included drywall anchors into the drilled holes (1 per hole).
Secure the upper flue bracket to the wall using 3 no. 8 x 3/4" screws.
Ensure that the bracket is tight against the wall.
All manuals and user guides at all-guides.com
WARNING
WARNING
!
HD0813A
7
36
/
" =
8
42
7
/
" =
8
C
EILING
S
CREW LOCATIONS
HD0377
6
HE0233A
W
ALL STUDS
F
RAMING BEHIND DRYWALL
24"
BOTTOM OF HOOD
ABOVE COOKTOP
30"
BOTTOM OF HOOD
ABOVE COOKTOP
C L
M
OUNTING BRACKET
FLUSH WITH CEILING