Install The Hood; Connect The Wiring - Broan Elite E60000 Serie Instructions

Masquer les pouces Voir aussi pour E60000 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13. INSTALL THE HOOD

Hold the hood until it is completely secured to the wood
mounting strip.
I
(
)
NTERNAL BLOWER
S
ONLY
Run power cable to installation location. Remove the electrical compartment cover.
Insert the cable in the hood and tighten the wire clamp to secure the cable.
A
LL INSTALLATIONS
Rest the back cavity of the hood on the wood mounting strip.
Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4'' (for 30'' and
36'' width hoods) or (6) screws (for 42'' and 48'' width hoods) provided at locations shown. Drill (3) 3/16'' size holes into the
drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the three wall
anchors with the remaining no. 8 x 3/4'' screws and the (3) washers provided.
For a non-ducted installation, go to step 15, Connect the wiring.
14. ROUGH-IN PLATE LOCATION
Run power cable to installation location. For ducting through top of hood, existing
plate remains in place on inside back of hood.
For ducting through back of hood, remove existing plate from inside back of hood
and remove the rough-in plate from the top of hood. Attach the plate to inside top
of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the
rough-in plate to the back of hood so that the wiring box is located on the right
side as you are facing the hood.
Connect ducting to rough-in plate as you are installing the rough-in plate. Use
duct tape to make all joints secure and air-tight.

15. CONNECT THE WIRING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate or electrical compartment and set aside.
INTERNAL BLOWERS:
The ORANGE wire (A) is for make-up air device connection only.
If there is no make-up air device, never remove the cap on the
ORANGE wire end.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
CAUTION
(ALL BLOWERS)
Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under GREEN ground screw.
CAUTION
Reinstall wiring cover.
(EXTERNAL BLOWERS HOODS ONLY)
WARNING
!
- 11 -
M
OUNTING SCREWS LOCATION
HD0264
W
ALL ANCHORS LOCATION
R
-
OUGH
IN PLATE
ON TOP OF HOOD
L
OCKNUTS
L
OCKNUTS
HD0262
P
LATE ON BACK OF HOOD
HE0088
W
IRING
COVER
A

Publicité

Table des Matières
loading

Table des Matières