  • FRANÇAIS, page 13
Commissioning
Programming
Guideline to fast, trouble-free
commissioing of the
Siedle DoorCom ISDN DCI 600-...
at an internal S0 bus of an ISDN
telecommunication system
(ISDN TC system).
10
Operating and display elements
There are two LEDs and a pushbut-
ton available for use as operating
and display elements.
The two LEDs are used to display
the operating modes:
Green LED on constantly =
Operational
Green LED blinking =
Software downloading
Red LED on constantly =
Error
Red LED blinking constantly =
No executable program
Red LED flashing =
Programming enable status
Commissioning
• Installation of the entire system is
completed and free of faults.
• Connection of the DCI to an
internal S0 bus of an ISDN TC
system has taken place.
Programming
Insert the supplied CD with the pro-
gramming software in the CD drive.
Autorun will start the installation
automatically, or alternatively start
the installation manually by double
clicking on Setup.exe. DoorCom
must be programmed with a PC,
whereby three different interfaces
are available.
• RS485 with our PRI 602-0
• RS232 programming interface
with PC directly on site.
• Remote configuration via the
public network.
For remote configuration, however,
a call number must have been pre-
viously programmed under "Own
MSN" to allow the DCI to be dial-
led.