Télécharger Imprimer la page

Kärcher HDS 891 ST Notice D'instructions page 36

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
English
Frequency
Action
Six-
Change oil
monthly or
after 1000
operating
Check, clean Whole unit
hours
Annually
Safety
inspection
2. Maintenance Contract
A maintenance contract for this unit can be
concluded with the responsible KÄRCHER
Sales Office.
3. Cleaning The Strainer
Strainer in the water inlet
Shut off the water inlet,
Unscrew the water inlet hose off the unit,
Push the strainer out of the connection with
a screwdriver,
Clean the strainer,
Re-install in reverse sequence
D2
D. Maintenance
Applicable assembly Procedure
Pump
Whole unit
Drain oil. Fill up with new oil,
order no. 6.288-016.
Check the level on the oil reservoir.
Visually inspect the unit,
check the high-pressure
connections for leaks,
check the overflow valve for leaks,
check the high-pressure hose,
check the pulsation damper,
clean/replace the fuel filter,
decarbonise, descale the heating coil,
clean/replace the ignition
electrodes,
clean/replace the burner nozzle,
adjust the burner
Safety inspection in accordance with
Directives for liquid spraying devices
Strainer in the water level sensor
Remove the panels
Unscrew the hose off the float tank on the
high-pressure pump
Screw an M8x30 screw into the strainer
Pull out the screw and strainer with pliers
Clean the strainer
Re-install in reverse sequence
5.959-742 A 2009651 (11/04)
HDS 891 / 1291 ST
By whom
Operator
Customer
service
Expert

Publicité

loading

Ce manuel est également adapté pour:

Hds 1291 st