LIMITATIONS

The peripheral pumps of the MULTIOIL range have been designed to pump gas oil, fuel oil from tanks and dockyards.
They are specially suitable for use in farms, building sites, shipyards, and in both industrial and residential applica-
tions.
The pipes supplied with the Multioil kit are designed for oil flow but are not guaranteed for oil contained therein for
long time. After each use, drain and clean them on a regular basis. Using the pipes with fluids other than gas oil and
water cannot guarantee the product integrity.
Pipes must not be directly exposed to the action of atmospheric agents: very high or low temperatures, heat or
direct exposure to sun could impair their quality and break them.
WARNING
The pump is not suitable for pumping salt water or dirty water for the supply of drinking water, corrosive
fluids or fluids containing abrasive materials (such as sand). Should the pumped fluid contain sand or other
abrasive particles, we recommend using a filter.
WARNING
If used with tanks above 1000 litres, a trigger-type delivery gun must be used.
TECHNICAL DATA
Mains voltage / Frequency
Absorbed power
Type of protection
Suction fitting
Delivery fitting
flow rate
head
Maximum suction height including load losses
Power cable
Motor
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid
Maximum number of starts per hour
Sound power level (Lwa)*
Sound pressure level (Lpa)
Sound emission values obtained in conformity with the EN 12639 standard
* Measurement method according to EN ISO 3746
8
MULTIOIL
230 V ~ 50 Hz
550 Watt
IPX4
33,25 mm (1"F)
33,25 mm (1"F)
min. 300 l/h - max. 2.100 l/h
min. 4 m - max. 35 m
5 m con valvola di fondo
H07RN-F
Single-phase, continuous-operation motor.
External ventilation, with condenser always ON
8,6 Kg
3 mm
6.5 bar
5° C
40° C
35° C in continuous mode
30 uniformly distributed
80 dB
68,6