Safety
2.1
General safety notes
The manuals for the system and parts thereof as well as the maintenance records and handover certificates must be kept
available near the system.
During installation, operation, maintenance or repair of the system, the regulations for the prevention of accidents, the perti-
nent DIN and VDE standards and directives, as well as the directives of the local power supply industry must be heeded.
NOTICE
Disconnect system from energy sources!
Ensure that the electrical components are disconnected from the electrical power supply during the work.
WARNING
Live parts
Heed the following points when working on electrical cables and connections.
The national regulations concerning electrical safety apply to all connections and installation work.
The system must be supplied through a residual current protection device (RCD) with residual current of not
more than 30mA.
The control unit and the float switch or level control are live and must not be opened.
It must be ensured that the electric cables as well as all other electrical system components are in a faultless condition. In
case of damage, the system may on no account be put into operation or must be stopped immediately.
WARNING
Danger due to overvoltage!
Operate the system only in buildings in which an overvoltage protection system (e.g. surge arrestor, type 2 per
VDE regulations) is installed. Interference voltage can seriously damage electrical components and lead to sys-
tem failure.
2.2
Personnel - qualification
The relevant operational safety regulations and the hazardous substances ordinance or national equivalents apply for the
operation of the system.
The operator of the system must:
prepare a risk assessment
identify and demarcate corresponding hazard zones
carry out safety training
secure the system against unauthorised use.
Person
1)
Operating company
Technical expert, (familiar with,
understands operating instructions)
Electrical specialist VDE 0105 (per regulations
for electrical safety, or per national equivalents)
1) Operation and assembly work may only be carried out by persons who are 18 years of age.
2.3
Intended use
The control unit represents the control of a lifting station or a pumping station for wastewater. Probes, float switches or pres-
sure sensors can be used to detect the level. When the switching level has been reached, the pump-off function is activated.
When the level has fallen accordingly, pumping off is ended automatically.
For certain pumps, it may be necessary to set the motor protection switch (see "Technical data", page 28)
WARNING
The control unit itself is NOT intended for installation in an EX zone!
All:
modifications or attachments
use of non-genuine spare parts
repairs carried out by companies or persons not authorised by the manufacturer
not explicitly authorised by the manufacturer in writing can lead to a loss of warranty.
26 / 144
Approved activities on KESSEL systems
Visual inspec-
tion, inspection
Installation and operating instructions
Functional check, config-
uration of the control unit
Work on electri-
cal installation
010-700_04