Emitter Connections - schmersal SLC 412 Instructions De Montage Et De Raccordement

Barrières immatérielles de sécurité
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EMITTER CONNECTIONS

PIN
COLOUR
Brown
1
White
2
RANGE/TEST1
Blue
3
Black
4
RANGE/TEST2
Grey
5
PIN 2
+24 VDC
0 VDC *
0 VDC *
+24 VDC
* (0 VDC or open circuit)
2
3
NAME
TYPE
24VDC power supply
24VDC
IN
INPUT1 for range/test
SEL
IN
IN
0VDC
INPUT2 for range/test
SEL
IN
-
PE
RANGE and TEST SELECTION
PIN 4
0 VDC *
+24 VDC
0 VDC *
+24 VDC
1
5
4
DESCRIPTION
see table "RANGE and TEST
selection
SELECTION"
0VDC power supply
see table " RANGE and TEST
selection
SELECTION"
Ground connection
Table 1
LOW range (Refer TECHNICAL DATA )
HIGH range (Refer TECHNICAL DATA )
EMITTER IN TEST CONDITION
Condition not allowed
Table 2
FUNCTIONING
Protected with 2A fuse
-
-
MEANING
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Slg 412