Electrical

Disconnect power before working on pump, motor, pressure switch, or wiring.
MOTOR SWITCH SETTINGS
Dual-voltage motors (motors that can operate at either
115 or 230 volts), are set at the factory to 230 volts. Do
not change motor voltage setting if line voltage is 230
volts, or if you have a single voltage motor.
NOTE: Never wire a 115 volt motor to a 230 volt line.
Remove Motor End Cover
If you have a dual-voltage motor, and will connect it to
115 volts, follow the procedure below.
End Cover Screws
Motor
End Cover
Figure 6: Removing Motor End Cover
You will need to remove the motor end cover to change
the voltage setting.
Your motor terminal board (located under the motor end
cover) should look like that shown below.
Ground
Screw
Voltage
Change Dial
Figure 7: Voltage set to 230 volts, Dial Type
4693
Power Lead
Terminals
4695
To change to 115 volts:
Step 1. Make sure power is off.
Step 2. Turn the dial counter-clockwise until 115 shows
in the dial window.
Step 3. The wires from the pressure switch should
already be attached to to power lead terminals.
Step 4. Reinstall the Motor end cover.
Pressure Switch Wiring
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Figure 8: Pressure Switch Wiring
Step 5. Go to Wiring Connections below.
Hazardous voltage. Can shock, burn, or
kill. Connect ground wire before connecting power
supply wires. Use the wire size (including the ground
wire) specified in the wiring chart. If possible, connect
the pump to a separate branch circuit with no other
appliances on it.
Explosion hazard. Do not ground to a gas
supply line.
WIRING CONNECTIONS
Fire hazard. Incorrect voltage can cause
a fire or seriously damage the motor and voids the
warranty. The supply voltage must be within ±10% of
the motor nameplate voltage.
NOTICE: Dual-voltage motors are factory wired for 230
volts. If necessary, reconnect the motor for 115 volts, as
shown. Do not alter the wiring in single voltage motors.
Install, ground, wire, and maintain your pump in
compliance with the National Electrical Code (NEC) in the
U.S., or the Canadian Electrical Code (CEC), as applicable,
and with all local codes and ordinances that apply.
Consult your local building inspector for code information.