Pentair BERKELEY 5FN-L Manuel D'utilisation page 6

Systèmes de pompes enfonte montées sur réservoir pour puisage en eau peu profonde
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Discharge Pipe and Pressure Tank Connections
PRE­CHARGE TANk CONNECTION
(FIGURE 4)
Step 1. Install two tees in the pump discharge port (see
Figure 4). The pipe size must be at least as large
as the discharge port.
Step 2. Run a pipe or reinforced hose from one arm of
the first tee to the port on the pre-charged tank.
Step 3. Connect the other end of the discharge tee to
your plumbing system.
Step 4. Check the pre-charge of air in the tank with an
ordinary tire gauge. The pre-charge should be
2 PSI less than the cut-in setting of the pump's
pressure switch. The pre-charge is measured
when there is no water pressure in the tank. Your
new pump has a 30/50 PSI switch, so adjust the
tank pre-charge pressure to 28 PSI.
Congratulations! You have just completed the
tank connection for your jet pump.
Please go to Page 7 for electrical hookup.
To Household
Water System
Pressure
Switch
Figure 4: Pre-charged Tank Connections
Motor
Model
HP
5FN-L
1/2
7FN-L
3/4
5PN, 05PNS11S
1/2
7PN, 07PNS11S
3/4
07SJH11C
3/4
10SJH11C
1
Pump Priming
Tee and Plug
From Well
Check
Valve
2349 0396
Wiring Chart – Recommended Wire and Fuse Sizes
Branch
Max.
Fuse
Load
Rating
volts
Amp
Amp
115/230
9.4/4.7
15/15
115/230 12.4/6.2
20/15
115/230
9.4/4.7
15/15
115/230 12.2/6.1
20/15
115/230 14.8/7.4
20/15
115/230 19.2/9.6
25/15
STANDARD TANk CONNECTION
(FIGURE 5)
Step 1. Install one tee in the pump discharge port (see
Figure 5).
Step 2. Run a pipe from the pump discharge port to the
inlet port of your tank. The pipe size must be at
least as large as the discharge port.
Step 3. Remove the 1/8" NPT pipe plug from the pump
Air Volume Control (AVC) port (see Figure 5).
Run tubing from the pump's AVC port (see Figure
5) to the port on the AVC mounted on the tank.
See instructions provided with tank and AVC for
details. AVC port location will vary, depending on
your pump model (see exploded view, Page 9).
Congratulations! You have just completed the
tank connection for your jet pump.
Please go to Page 7 for electrical hookup.
To Household
Water System
Pump
Priming Tee
and Plug
Pressure
Switch
Figure 5: Standard Tank Connections
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 ­ 100
101 ­ 200
(0 ­ 30)
(31 ­ 61)
AWG WIRE SIZE (mm
14/14(2/2)
10/14(5.5/2)
12/14(3/2)
10/14(5.5/2)
14/14(2/2)
10/14(5.5/2)
12/14(3/2)
10/14(5.5/2)
12/14(3/2)
8/14(8.4/2)
10/14(5.5/2)
8/14(8.4/2)
Air Volume
Control
Air Volume
Control Tube
From
Well
Check
Valve
2350 0396
201 ­ 300
301 ­ 400
(62 ­ 91)
(92 ­ 122)
)
2
10/14(5.5/2)
6/14(14/2)
8/14(8.4/2)
6/12(14/3)
10/14(5.5/2)
6/14(14/2)
8/14(8.4/2)
6/12(14/3)
6/14(14/2)
6/12(4/3)
6/12(14/3)
4/10(21/5.5)
6
401 ­ 500
(123 ­ 152)
6/12(14/3)
6/12(14/3)
6/12(14/3)
6/12(14/3)
4/10(21/5.5)
4/10(21/5.5)