Lighting connection on Control Center
1 - Connect the lighting as descrided bellow depending the power of the lighting.
Total lighting power is less than 1600 W
< 1600W
Heater connection on Control center
Connection on the heater flow switch
1 - Connect the heating pump as desbrided bellow.
Make sure the heater is equipped with a built-in overheating protection!
Connection through a contactor
1 - Connect the heating pump as descrided bellow.
12
NEUTRAL (N)
PHASE (L)
serial connection
HEATING
FLOW-SWITCH
Total lighting power is more than 1600 W
> 1600W
The piloting of the heating is done in series on the flow-switch. The original heating safety is
maintained.
> Set the heating on maximum temperature.
A1
A2
A1
A2
NEUTRAL (N)
EARTH
PHASE (L)
NEUTRAL (N)
EARTH
PHASE (L)