Télécharger Imprimer la page

Zodiac BARACUDA G4 Guide Du Propriétaire page 8

Piscine hors-sol nettoyeur automatique
Masquer les pouces Voir aussi pour BARACUDA G4:

Publicité

Les langues disponibles

Les langues disponibles

Page 8
ENGLISH
Clearing the Diaphragm
Use the Quick Access Cassette system
to quickly clear the diaphragm or check it
for damage.
To remove:
1. Unscrew the cassette and pull it out
of the cleaner.
2. Loosen the cassette chamber; pull out
the inner pipe and diaphragm.
3. Pull off the diaphragm.
Inspect it for debris or wear, and rinse it
thoroughly with water. Replace if necessary.
To reinstall:
1. Verify that the retaining ring is on
the diaphragm.
2. Push diaphragm onto inner pipe.
3. Pull inner pipe and diaphragm through
until the diaphragm seats against the lip.
4. Reconnect the cassette and reinstall
on cleaner.
Replacing the Foot Pad
The foot pad should be replaced when the depths
of the channels between the treads are 3 mm (1/8 in.)
or less. Contact your Zodiac Dealer for assistance with
replacing this part.
Storage and Winterizing
Never coil the hose. Store the G4 out of direct sunlight.
When storing for the winter, drain all water from the cleaner. Remove all connectors
and adapters from the dedicated suction line or skimmer. Store the disc flat, and hose
sections disconnected, drained and straight.
®
®
Zodiac
Baracuda
G4 Automatic Aboveground Pool Cleaner
|
Inner Pipe
Retaining
Ring
Diaphragm
Cassette
Chamber
Channel Between Threads
Owner's Manual
Cassette
Chamber

Publicité

loading