Operation; Setup - Titan AirCoat Série Mode D'emploi

Masquer les pouces Voir aussi pour AirCoat Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

4.
Operation
This equipment produces a fluid stream at extremely
high pressure. Read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
4.1

Setup

1. Make sure the siphon hose (fig. 5, 1) is connected to the fluid
section (2) and the bleed hose (3) is connected to the bleed
valve (4).
Spider models - Make sure the siphon tube is threaded into
the fluid pump and tightented wrench tight.
2. Thread the suction tube filter (5) onto the metal suction tube.
4
2
1
3. Lock the gun by flipping the trigger lock into lock position
(see spray gun manual).
4. Using a wrench, attach a minimum of 50' of 1/4" nylon airless
spray hose to the material outlet fitting (fig. 6, item 1) on the
pump. Tighten securely.
5. Attach the spray hose to the material inlet fitting on the spray
gun. Using two wrenches (one on the gun and one on the
hose), tighten securely.
3
5
2
1
GB
Make sure all airless hoses and spray guns are
electrically grounded and rated for at least 2800 PSI
(19 MPa) fluid pressure.
6. Attach the air hose to the air outlet fitting (fig. 6, item 2) on
the sprayer. Tighten securely.
7. Attach the air hose coupling to the air inlet fitting on the spray
gun. Attach the air hose to the coupling. Tighten securely.
Reversing the hose connections could result in
serious injury. Make sure the airless spray hose is
connected from the material outlet fitting on the
sprayer (1) to the material inlet fitting on the gun
and the air hose is connected from the air outlet
fitting on the sprayer (2) to the air inlet fitting on the
gun.
8. Fill the oil cup 1/2 full with Piston Lube (P/N 314-480). This
extends packing life.
Piston Lube prevents increased wear and tear to the
packings.
Attention
9. Verify that the air compressor meets the power requirements
necessary to effectively power the sprayer. See "Technical
Data", section 3.4 to determine air requirements.
i
The requirements will vary on each model.
10. Prior to connecting the compressor to the unit, perform the
following in order to prevent accidental startup:
a.
Close the shutoff valve (fig 7, item 1). The figure shows the
handle in the closed position.
b.
Turn the air regulator (2) fully counterclockwise to its lowest
pressure setting.
c.
Open the bleed valve (3) by turning it fully counterclockwise.
The bleed valve handle should be pointing down.
11. Using a wrench, remove the red plug from the air hose fitting
(Fig. 8, item 1). Attach the air hose and tighten wrench tight.
All units are equipped with a 3/8" NPT (M) nipple.
8
1
2
4
5
3
AirCoat

Publicité

Table des Matières
loading