5.6 The motor and the blow pipe
5.6.1 To disassemble the motor and the blow pipe
1. Loosen the connector (A) from the control unit. Make
sure not to cause damage to the connector (B) or
the cables. Loosen the connector/cable from the
connection spring.
2. Lift the blow pipe and motor housing out of the
chassis.
3. Loosen the screws and the brushes/cables (D). Lift
off the blow pipe from the motor housing. Make sure
the rubber seal (E) comes loose from the pipe.
D
E
4. Attach the shaft (F) to the motor. Use an M4 screw
as a puller and screw it onto the shaft (G) to remove
the fan.
F
12 - Repair instructions
5. Loosen connector (H) from the connection spring in
A
B
6. Loosen the screws attaching the motor in the motor
C
7. Lift the motor out of the motor housing.
5.6.2 To assemble the motor and the blow pipe
Note: Make sure the cables are put correctly to prevent
them from being caught between the chassis halves.
G
the motor housing.
H
housing.