INDICATION
ACTION
3
Deactivation posi-
tion of input PH
4
Confirm
deactivation of
input PH and exit
the set-up mode
Y
ATTENTION! After the set-up, test the security device operation connected to input PH, de-
scribed in table 5 for DIP10 switch.
8.
INDICATION
During operation, the indication of LED 1 (Fig. 13) of the control station informs on the drive
operation and failures (table 8).
INDICATION
lights continuously
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
TR-3019-230E-ICU / TR-3019-400E-ICU
SETUP OPERATIONS
Use the button
or the button
door leaf to the required position, from which input
PH will be deactivated
Press and hold the button
buttons simultaneously
buttons at least 3 seconds.
When the LED fades (there will be no rapid flashes),
release the buttons in the reverse sequence.
Exit to Standby mode will occur automatically after
the LED fades
DESCRIPTION
button is pressed or input S is activated (table 2, connector XP3), or motor thermal
protection is activated.
Performing door movement commands is not allowed; stop of the movement
End position.
Stop of the movement in the set end position
Input PH is activated (table 2, connector XP3).
Performing door closing commands is not allowed
Input SE is activated (table 2, connector XP7).
Preforming door closing commands is not allowed
A failure occurs during automatic verification of safety devices connected to the input
PH (table 5, DIP5).
Performing door closing commands is not allowed.
Motion absence error.
Stop operation
End positions are not set (Section 6).
Performing door movement commands is not allowed
Encoder error (incorrect encoder signal, malfunctions).
Performing door movement commands is not allowed; stop of the movement
Power voltage value is out of operation range.
Performing door movement commands is not allowed
Time of continuous door movement in one direction (70 s) is exceeded.
Stop of the movement
to set the
. Then press both
and hold all the
Table 8
43