SETTING THE OPERATION PARAMETERS
ACTION
5
Exit the set-up
mode
Y
ATTENTION! After the set-up, test the security device operation connected to input SE, de-
scribed in table 5 for DIP9 switch. The obstacle should be on the floor under the optical beams
of advanced optosensors (intersect the beams when closing).
7.2
ADDITIONAL SETTING OF DOORS POSITION
TO DEACTIVATE INPUT «PH»
The additional setting is active only when the final positions are configured (section 6), and
DIP10-ON and DIP1-ON switches are set (the doors are operated in pulse mode).
Y
ATTENTION! If DIP10 switch is set to OFF position and the drive power supply is turned off / on,
the previous additional setting will be deleted and DIP10-ON position will be set to the default
value (the additional setting should be made first).
For additional setting, all the operations should be performed sequentially and correctly (table 7).
If the setting is incorrect, the required deactivation place will not be configured! After the set-
up, a mandatory testing is required.
The setting is performed by means of the control panel (fig. 13). During the set-up, the movement
control is performed manually with the buttons
If you need to interrupt the setting operations and restart the setting again, wait 30 seconds
before exiting the set-up mode automatically, or turn off and on the drive supply voltage with
the line circuit-breaker (fig. 4).
ACTION
1
Enter the set-up
mode
2
Enter the set-up
mode to deactivate
input PH
42
42
SETUP OPERATIONS
Exit to Standby mode will occur automatically after
the LED fades
SETUP OPERATIONS
Press and hold the button
buttons
simultaneously and hold all
the buttons for at least 3 seconds. When the LED
starts flashing at interval of 1 second, release all
the buttons.
ATTENTION! When the LED flashes, it means being
in the set-up mode and waiting (up to 30 seconds)
for the next action
Press and hold the button
8 seconds.
When the LED starts flashing rapidly, release the
button
and
(by pressing and holding the button).
. Then press both
for at least
TR-3019-230E-ICU / TR-3019-400E-ICU