Technical Data; General; Mechanical; Electrical - Videotec NXW Manuel D'instructions

Masquer les pouces Voir aussi pour NXW:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9 Technical data

9.1 General

constructed from electropolished stainless steel
(Austenitic alloy stainless steel, corrosion and heat
resistant according to the following standards):
- UNI 6900-71: X 2 Cr Ni Mo 17 12
- AISI: 316L
- DIN 17006: X 2 Cr Ni Mo 18 10
- N° WERKSTOFF: 1.4404
- AFNOR: Z2 CND 17-12
- BSI: 316 S 12
The screws utilised are in austenitic alloy stainless
steel, corrosion and heat resistant according to the
following standards:
- UNI 6900: X 5 Cr Ni Mo 1712
- AISI: 316
- ISO quality: A4
- Resistance class ISO: 80
Supplied with instruction manual, desiccant bag,
accessories for camera and lens mounting
UNI: Ente Nazionale Italiano di Unificazione, AISI: American Iron and
Standard Institute, DIN: Deutsche Industrie Normen, AFNOR: Association
Française de Normalisation, BSI: British Standard Institution, ISO:
International Organization for Standardization

9.2 Mechanical

2xPG13.5 cable glands in nickel-plated brass for external
connections
2x1/2"GAS connectors for liquid input / output
1x1/4"GAS connector for air barrier input
External body polishing
O-ring gaskets
9mm (0.35in) thick back flange
Window: internal Ø 95mm (3.7in), external Ø 116mm
(4.6in)
External dimensions: Ø 154mm (6.1in), length 375mm
(14.8in)
Internal usable dimensions (WxH): 78x78mm (3.1x 3.1in)
Unit Weight: 10.2kg / 22.5lb
Internal usable length
NXW
Internal usable length with camera power supply
NXW
345mm (13.6in)
280mm (11.1in)
Tempered glass
6mm (0.2in) thick
operating temperature 260°C (500°F), thermal gradient
108°C (226°F)
Vicor glass
6mm (0.2in) thick
Operating temperature 400°C (752°F), thermal gradient
220°C (428°F)
IR-proof glass
6.6mm (0.25in) thick
operating temperature 260°C (500°F), thermal gradient
108°C (226°F)
IR radiation transmitted 21%
Cooling liquid
Application example with incoming water at 20°C (68°F)
temperature:
- T environmental 200°C (392°F), water flow 2 l/min
(0.5US gal/min), T housing internal 32°C (89.6°F)
- T environmental 300°C (572°F), water flow 2.2 l/min
(0.6US gal/min),T housing internal 41°C (105.8°F)
- T environmental 400°C (752°F), water flow 6.5 l/min
(1.7US gal/min), T housing internal 44°C (111°F)
Cooling Air
Application example with incoming air at 17°C(62°F) and
an environmental temperature at 80°C(176°F)
- pressure 1 Bar -flow rate 10 m³/h, the internal
temperature is about 45°C(113°F)
- pressure 2 Bar -flow rate 15 m³/h, the internal
temperature is about 35°C(95°F)
Air filtering
Pressure air flow 0.3-2.5 Bar, filter 0.1 micron
Air barrier
Max pressure 1Bar

9.3 Electrical

Camera power supply
- IN 230Vac - OUT 12Vdc, 50/60Hz, 400mA
- IN 230Vac - OUT 24Vac, 50/60Hz, 400mA

9.4 Environment

Indoor / Outdoor

9.5 Compliance to

CE according to EN61000-6-3, EN60065, EN50130-4
IP66 according to EN60529
9

Publicité

Table des Matières
loading

Table des Matières