Starting the regeneration process after the display
shows
(optional)
- Press the key
P
and select program
- Press
, then press the Start/Stop key
Starting the regeneration process after the display
shows
(obligatory)
- Program
is already shown on the display.
- Press
, then press the Start/Stop key
The steam generator drains. Wait till the buzzer sounds.
The display now shows
Remove the lid from the water softener compartment.
Confirm by pressing
.
Wait until the buzzer sounds and the display shows
.
Check that the water level in the base exchanger is just
below the filler inlet.
Fill with 0.5 kg of regeneration salt; use salt measuring
cup.
Close the lid of the water softener compartment.
Confirm by pressing
; the buzzer stops buzzing.
For 15 seconds, the conductivity of the water is measu-
red (1 to 3 times). There is an audible flow of water
through the base exchanger.
If the conductivity is OK, the remaining-time display
will show the regeneration time
regeneration process is carried out.
If no salt was filled in, but instead only the confirmation
key
was pressed (conductivity insufficient), press
the
key again.
The display now automatically shows
Repeat the entire process.

6.16 Switching-off

Press
. The appliance is now switched off.
After 5 minutes, the boiler will be drained automatically.
We do not recommend switching the appliance off until it
is no longer needed. This will prevent drainage of the
boiler and the appliance will remain on standby.
You save energy. At the same time the regeneration
cycle will be extended because the boiler needs to be
filled less often.

6.17 Possible external connections

Salvis Kitchen control system
Precondition: Interface RS485 activated in the appliance.
Main modules among others:
- Monitoring of units, with automatic
HACCP-documentation
- Energy optimization
- Monitoring of temperature in cold-storage depot
- Device control from central control area
- Early-warning and alarm protection
Salvis Data-manager
.
Precondition: Interface RS232 activated in the appliance.
.
Connection to PC by means of an converter cable.
Features: Management of all cooking programs for
Combi-Steamer and Steamer. Recording of new pro-
grams as well as up- and download to the appliances.
Journal printer HACCP
The journal printer must be logged into the control and
the language must be selected (service program).
.
The printing interval can be changed by the user as
follows:
- Switch off the control.
.
- Keep key
- The time display shows the current interval in minutes.
- The input mode can be obtained by pressing key
and the new interval can be entered by means of
numerical keys. The input is confirmed with key
Every time a cooking process is started, the printout is
automatically started if the printer is switched on. It is
also possible to printout the counters and the service
parameters by means of pressing the keys
in the select mode (LED blinking).

6.18 Operating error messages

in minutes. The
These appear in 2 digits in the time display and the
buzzer sounds.
.
Press

6.19 Fault messages

These appear in 2 digits in the time display and the
buzzer sounds.
If one of these faults is displayed, switch off appliance.
The buzzer stops. Call service centre.
- 37 -
P
depressed and switch on control
.
appears on the program display.
Core temperature sensor is not inserted or
the temperature entered is lower than the
temperature measured.
In a cooking phase, the values entered
have been lost. Switch off appliance and
recall program again.
to cancel buzzer.
Cooking chamber sensor interruption
Cooking chamber sensor short circuit
Level probe thermoelement interruption
Level probe thermoelement short circuit
Timeout water level
Timeout pressure switch
Safety pressure switch cooking chamber
Problem heating contactor
Core temperature sensor interruption
(work may be continued without sensor).
Core temperature sensor short circuit
(work may be continued without sensor).
Conductivity of water after regeneration to
high. Repeat regeneration without salt.
.