ELECTRONIC BATHROOM SCALE - BODY FAT ANALYZER
MEMORY FUNCTION
The product features 10 personal memory settings.
This allows users to store height, activity level, age,
gender athlete /normal for frequent usage.
To store Memory
1. Follow steps 1-9 in Body Fat and Body Water
measurement mode procedure.
2. Press [ ▲ / ▼ ] to select the memory location and
the memory figure will be blinking.
3. If the selected memory location is occupied, it
will display " ■■ " below the memory figure.
4. Press [
] to store your personal data to the
desired memory location with 1 long beep. «
and " ■ " icons will be shown on the screen, the data
is memorized.
To Recall Memory
1. Press and hold [
while in power off mode. It will enter recall mode.
2. Press [ ▲ / ▼ ] to select the memory location.
3. If the selected memory is unoccupied, no
previous input will be displayed.
4. If the selected memory is occupied, press
▲ and ▼ at the same time to clear the contents
of the selected Memory.
5. If the selected memory is occupied, press [
to confirm the desired memory with 1 long beep.
«
R » icon will be displayed on the display. The
R
height, activity level, age, gender and athlete /
normal of the memory will be displayed on the
screen.
6. Finally, repeat steps 10 to 12 as illustrated above.
Fast Recall Mode of Memory
1. When your bathroom scales are switched off,
press ▲ or ▼ to switch from one memory to the
other: the screen displays the numbers in the
memory. Press [
2. The «
R » icon appears and the size, activity
R
level, age, sex and Athlete/ Normal mode as well.
20
28/01/08
11:34
ON
] button for 2 seconds
] to confirm the entry.
Page 20
POWER OFF
In the body fat memory or recall mode, press and
hold [ ON ] for 2 seconds, the unit will turn off.
SPECIAL DISPLAYS
Display
Err0
Incorrect initialisation: begin again as
explained above.
Err1
Unstable weight: begin again.
Err2
Overload: remove weight immediately.
Err3
Body impedance exceeds the limit
(100 ohm - 1kohm): begin again.
For certain skin types an Err3
reading may occasionally appear.
In this case you may need to
R »
R
dampen your feet to improve the
contact with the electrod
Err4
Percentage of body fat above the
4%-50% bracket: begin again.
Err5
Percentage of body water is beyond
the range. Clean the bottom of feet
with damp cloth and step on the
scale again
Lo
Battery failure: replace it.
PROTECT THE ENVIRONMENT
Dispose of used batteries in a designated
container so that they can be collected and
recycled. Do not mix different types of
]
batteries. Do not mix new and used
batteries.
After life, dispose of this product at a designated
waste recycling point.
WARRANTY
This impedance scale is guaranteed for 2 years
against defects in materials or manufacturing.
During this period, any such defects will be repaired
free of charge (proof of purchase must be shown in
the case of a complaint under warranty).
The warranty does not cover damage resulting from
improper use or negligence. In the event of a claim,
first contact the shop where you purchased your
scale.
In the case of: