10.1 Mounting
The housing has to be mount on a wall as represented below ::
C24
(3 screws)
10.2 Wall remover detection switches
C24: 1 switch for both
housing tamper and
housing snatch
A screw on the wall have to be install in the
housing hole indicate in ANNEX to detect a tear
down.
This screw must extend out of the wall by 55mm
+/-1mm
10.3 Battery
Batteries integration drawing and wiring schematics are available in APPENDIX.
*Capacities of batteries to be associated are listed in Table Capacity Battery §9.11.
10 Installation of your equipment
C38
(4 screws)
C24 switch – C38 – C85 switch
21
C85
(4 screws)
C38 – C 85: 1 switch for
housing tamper and a
switch for housing snatch
A screw on the wall have to be install in the
housing hole indicate in ANNEX to detect a tear
down.
This screw must extend out of the wall by 24mm +/-
1mm