3. Technical data

Number of lubrication outlets
Suitable grease
Maximum pressure
Maximum tube length between the
lubricator and the lubrication point
Dispense rate
Power supply
Power consumption, maximum
Power supply connector
Alarm conditions
Steering
Ambient temperature
IP rating
Lubrication tubes
Boundary dimensions
Weight
Note:
The dispense rate is based on a continuous supply of grease over a 24 hour period.
If external steering is used, the dispense setting needs to be corrected.
If, for example, the SKF DialSet program recommends 3 cc/day and the lubricator
will only dispense grease 8 hours/day, the dispense rate must be increased to
24 hours / 8 hours x 3 cc/day = 9 cc/day.
SKF LAGD 400
1 - 8
NLGI 1, 2 and 3
40 bar (600 psi)
5 m (16 ft)
0,1 - 10 cm³/day
(0.003 -0.35 US l.oz/day) per outlet
approx. 0,6 - 65 g/week
(0.02 - 2.3 oz/week) depending on
grease density
100 - 240 VAC (50 - 60 Hz) or 24 VDC
12 W
DIN 43650 -Micro
blocked feed lines, empty cartridge;
internal and external
the lubricator can be switched on and off
by an external relay
0 - 50 °C (32 - 120 °F)
54
20 m (65 ft), Nylon, 6 x 1,5 mm
170 x 130 x 530 mm (7 x 5.5 x 21 in)
3,4 kg (8 lb)
7