4.7 LAPN connection nipples
Designation
LAPA 45
LAPA 90
LAPN 1/8
LAPN 1/2
LAPN 1/4
LAPN 3/8
LAPN 6
LAPN 8
LAPN 8x1
LAPN 10
LAPN 10x1
LAPN 12
LAPN 12x1,5
5. Operation of the lubricator
5.1 How to switch the lubricator on
Apply power to the unit. OFF appears on the display to show that the lubricator does not
dispense grease. To start the lubricator, push the ON/OFF button. The display shows the
current dispense rate of 5 cm³/day. The PUMP symbol shows on the display at the end of
each lubricator stroke.
5.2 Adjustment of dispense range
The dispense rate can only be adjusted when the unit is OFF. Push the SET-button.
The display shows the current dispense rate. Push the +/- buttons to adjust the dispense
rate to the necessary value. The dispense rate is increase in steps as shown in the table.
Dispense range
cm³/day
0,1 to 0,2
0,2 to 0,5
0,5 to 1,0
1,0 to 2,0
2,0 to 5,00
5,0 to 10,0
SKF LAGD 400
Step size
cm³/day
0,02
0,05
0,10
0,25
0,50
1,00
Description
Angle connection 45°
Angle connection 90°
Nipple G 1/4 - G 1/8
Nipple G 1/4 - G 1/2
Nipple G 1/4 - G 1/4
Nipple G 1/4 - G 3/8
Nipple G 1/4 - M6
Nipple G 1/4 - M8
Nipple G 1/4 - M8x1
Nipple G 1/4 - M10
Nipple G 1/4 - M10x1
Nipple G 1/4 - M12
Nipple G 1/4 - M12x1,5
Dispense range
US l.oz/day
0.003 to 0.010
0.010 to 0.020
0.020 to 0.050
0.050 to 0.100
0.100 to 0.200
0.200 to 0.350
Step size
US l.oz/day
0.001
0.002
0.005
0.010
0.025
0.050
11