6.
Technical specifications
Technical specifications
Item No.
Total connected load
Voltage fusing
Overall thermal output
Steam output
Appliance noise level
Tank/tub size
Max. filling level
Max. capacity
Frying surface
External dimensions
(WxDxH)
Weight
Water connection
We reserve the right to make technical changes!
7.
Installation and connection
D Note the weight of the appliance! Transport the appliance with a lift carriage or a forklift
truck.
D Follow the local technical regulations for kitchens.
D Installations must be carried out in accordance with the manufacturer's instructions,
following accepted technical regulations.
D Let customer service set up and install the appliance and provide an introduction.
D Observe the notes regarding safe operation, see page 23 chapter 1.
7.1
Installation
D Install
− horizontally and vibration free,
− under an extraction hood,
− not against flammable walls.
D Do not install appliances with a water supply next to deep-fat fryers! Maintain the minimum
distance of 900 mm or install a splash guard (sheet metal deflector) with a minimum height
of 350 mm.
. Remove protective foil from appliance. Remove residual adhesive with cleaner's naphtha.
800 Plus
941646, SM371450
13.5 kW
400 V 3N 50/60 Hz
7.88 kW
6.35 kg/h
less than 70 dB (A)
580 x 680 x 210 mm
60 litres
80 litres
580 x 570 mm
800 x 800 x 810 mm (without feet,
with closed hinged top cover)
approx. 170 kg
−
800 Plus W
942251 (Norway 951277)
959162, SM371451
13.5 kW
400 V 3N 50/60 Hz (230V 3 50/60Hz)
7.88 kW
6.35 kg/h
less than 70 dB (A)
580 x 680 x 210 mm
60 litres
80 litres
580 x 570 mm
800 x 800 x 810 mm (without feet, with
closed hinged top cover)
approx. 170 kg
G 3/4"
Supply temperature max. 50° C
Water pressure:
− min. 200 kPa (2 bar) dynamic
− min. 600 kPa (6 bar) static
en