Set up the cable links in a sequence as follows. Connect the power cable between device
and power supply only after all other connections have been made.
Protective caps
Prior to the first installation the pro-
tective plastic caps must be removed
from all the connections used at the
rear of the unit.
RCA connections
Mechanically identical RCA
plugs are available for analogue and digital out-
puts. Make sure that you do not get these connec-
tions confused during installation!
Make sure that you do not
mix up the analogue connec-
tors for right and left. The
RCA plugs for these are mostly colour coded as fol-
lows: red for the right channel, black or white for
the left channel.
Cable connections
Make sure that all plugs fit tightly. Inadequate con-
nections can cause noise interference, failures and
malfunctions.
- wrong -
To make the most of the components' sound poten-
tial, only high quality loudspeakers and connecting
cab les, for example Vincent cables, should be
used. Your local stockist will be glad to advise you
about this.
Vincent
32
INSTALLATION
DURING INSTALLATION PLEASE OBSERVE
THE FOLLOWING ADVICE:
1
2
O UT PU T
OU
- correct -
XLR connections
Note that European and US XLR signal use is diffe-
rent. This Vincent device uses the European system
in accordance with Standard AES14-1992 of the
Audio Engineering Society. The structure of the
cable is in any event the same. Provided both con-
nected devices meet the same standard, the signal
connection is correct. This is always the case if
both were manufactured by Vincent. If two devices
with different standards are connected, the signal
will then be inverted. In this case the signal use on
one side of the connection must be changed. Your
specialist dealer will assist you with this.
US System
1. USA System (Pin 2 = COLD, Pin 3 = HOT)
GND
COLD
2
1
3
HOT
European System
2. Europäisches System (Pin 2 = HOT, Pin 3 = COLD)
GND
2
1
HOT
3
COLD
Optical Connection
The dust cap protecting the optical
digital output should only be removed
if a cable is inserted. After a connection is remo-
ved from this socket, the cap should be replaced.