GUIDE DE MISE EN SERVICE RAPIDE
CONVERTISSEUR 1
2-WIRE
TRANSMITTER
P
PRESSURE
SENSOR 1
I
1
3
0
AUTO
MAN
1S1
2
4
3S1
Fig. 20: Schéma de câblage électrique du système multi-pompes (convertisseurs de fréquence
multiples), exemple 1C
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
CONVERTISSEUR 2
VACON 100 FLOW
VACON 100 FLOW
P1.2
Application
= Multipump(MultiDrive)
P1.2
Application
2-WIRE
P3.15.3 Pump ID Number
= 1
P3.15.3 Pump ID Number
TRANSMITTER
P3.15.4 Start & Feedback
= Signals Connected
P3.15.4 Start & Feedback
P
PRESSURE
SENSOR 2
1
+10V ref
Reference voltage
1
+10V ref
Reference voltage
I
2
AI1 +
2
AI1 +
NOT USED
NOT USED
(0...10V)
(0...10V)
3
AI1 -
3
AI1 -
4
AI2 +
4
AI2 +
PID FEEDBACK
PID FEEDBACK
(4...20mA)
(4...20mA)
5
AI2 -
5
AI2 -
6
+24V out
24V auxilary voltage out
6
+24V out
24V auxilary voltage out
7
GND
I/O ground
7
GND
I/O ground
8
DIN1
START FORWARD
8
DIN1
START FORWARD
FLUSHING
FLUSHING
9
DIN2
9
DIN2
(Start Forward + Flushing Freq.)
(Start Forward + Flushing Freq.)
PID SETPOINT SELECT.
PID SETPOINT SELECT.
10
DIN3
10
DIN3
(Open=Keypad SP1, Closed=Keypad SP2)
(Open=Keypad SP1, Closed=Keypad SP2)
11
CM
Common for DI1-DI6
11
CM
Common for DI1-DI6
1
3
0
AUTO
MAN
12
+24V out
24V auxilary voltage out
12
+24V out
24V auxilary voltage out
2S1
13
GND
I/O ground
2
4
13
GND
I/O ground
14
DIN4
FAULT RESET
14
DIN4
FAULT RESET
PUMP INTERLOCK
PUMP INTERLOCK
15
DIN5
15
DIN5
(Not in use by default)
(Not in use by default)
16
DIN6
EXTERNAL FAULT
16
DIN6
EXTERNAL FAULT
17
CM
Common for DI1-DI6
17
CM
Common for DI1-DI6
18
AO1 +
18
AO1 +
OUTPUT FREQUENCY
OUTPUT FREQUENCY
(0...20mA)
(0...20mA)
19
AO1 -
19
AO1 -
30
+24V in
24V auxilary voltage in
30
+24V in
24V auxilary voltage in
A
RS485
Drive-To-Drive
A
RS485
Drive-To-Drive
Communication
Communication
B
RS485
(Modbus RTU)
B
RS485
(Modbus RTU)
21
RO1
21
RO1
Relay Output 1
22
RO1
22
RO1
(RUN)
23
RO1
23
RO1
24
RO2
24
RO2
Relay Output 2
25
RO2
25
RO2
(FAULT)
26
RO2
26
RO2
32
RO3
32
RO3
Relay Output 3
(READY)
33
RO3
33
RO3
DIO´S
AI1
AO
DIO´S
AI1
FLOAT
U
U
FLOAT
U
GND
I
I
GND
I
RS485
AI2
termination
AI2
termination
U
OFF
U
OFF
I
ON
I
CONVERTISSEUR 3
VACON 100 FLOW
TRANSMETTEUR
P1.2
Applicatif
2 FILS
P3.15.3 Numéro d'identification de pompe = 3
P
P3.15.4 Démarrer et retour
CAPTEUR
DE PRESSION 3
I
1
+10 V
+
-
2
3
4
5
6
+ 24 V
7
8
9
10
11
1
3
0
AUTO
MAN
12
+ 24 V
2
4
13
14
15
16
17
18
AO1+
19
30
+24 V
A
RS485
o
RS485
21
22
23
24
25
26
32
33
E/S LOG
ISOLÉES DE LA TERRE
GND
CONVERTISSEUR 3
VACON 100 FLOW
= Multipump(MultiDrive)
P1.2
Application
= Multipump(MultiDrive)
2-WIRE
= 2
P3.15.3 Pump ID Number
= 3
TRANSMITTER
= Signals Connected
P3.15.4 Start & Feedback
= Signals Connected
P
PRESSURE
SENSOR 3
1
+10V ref
Reference voltage
I
2
AI1 +
NOT USED
(0...10V)
3
AI1 -
4
AI2 +
PID FEEDBACK
(4...20mA)
5
AI2 -
6
+24V out
24V auxilary voltage out
7
GND
I/O ground
8
DIN1
START FORWARD
FLUSHING
9
DIN2
(Start Forward + Flushing Freq.)
PID SETPOINT SELECT.
10
DIN3
(Open=Keypad SP1, Closed=Keypad SP2)
11
CM
Common for DI1-DI6
1
3
0
AUTO
MAN
12
+24V out
24V auxilary voltage out
3S1
2
4
13
GND
I/O ground
14
DIN4
FAULT RESET
PUMP INTERLOCK
15
DIN5
(Not in use by default)
16
DIN6
EXTERNAL FAULT
17
CM
Common for DI1-DI6
18
AO1 +
OUTPUT FREQUENCY
(0...20mA)
19
AO1 -
30
+24V in
24V auxilary voltage in
A
RS485
Drive-To-Drive
Communication
B
RS485
(Modbus RTU)
21
RO1
Relay Output 1
Relay Output 1
22
RO1
(RUN)
(RUN)
23
RO1
24
RO2
Relay Output 2
Relay Output 2
25
RO2
(FAULT)
(FAULT)
26
RO2
32
RO3
Relay Output 3
Relay Output 3
(READY)
(READY)
33
RO3
AO
DIO´S
AI1
AO
U
FLOAT
U
U
I
GND
I
I
RS485
RS485
AI2
termination
OFF
U
ON
I
ON
= Multi-pompe (multi-variateur)
= Signaux connectés
Tension de référence
ref
AI2+
NON UTILISÉ (0...10 V)
AI1-
AI2+
RETOUR PID (4...20 mA)
AI2-
Tension auxiliaire 24 V en sortie
out
GND
Terre E/S
DIN1
MARCHE AVANT
RINÇAGE (Marche avant + Fréq. rinçage)
DIN2
SÉL. POINT DE CONSIGNE PID
DIN3
(Ouvert = Panneau opérateur PC1, Fermé = Panneau opérateur PC2)
CM
Commun pour DI1-DI6
Tension auxiliaire 24 V en sortie
out
GND
Terre E/S
DIN4
RÉARMEMENT DÉFAUT
INTERVERROUILLAGE DE LA POMPE
DIN5
(Non utilisé par préréglage)
DIN6
DÉFAUT EXTERNE
CM
Commun pour DI1-DI6
FRÉQUENCE DE SORTIE (0...20 mA)
AO1-
Tension auxiliaire 24 V en entrée
entrée
Communication entre les
convertisseurs de fréquence (Modbus RTU)
RO1
Sortie relais 1 (MARCHE)
RO1
RO1
RO2
Sortie relais 2 (DÉFAUT)
RO2
RO2
Sortie relais 3 (PRÊT)
RO3
RO3
AI1
AO
U
U
I
I
terminaison
AI2
RS485
OFF
U
ON
I
VACON · 53
1