x 2
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
autoset
l. s w adj
opm1
2
1
opm2
2
1
clm2
-
2
1
clm1
-
2
1
ersu
o
+/-
Control unit
software version
stat
vers
OK
bft . . .
+/-
- +
No total
manoeuvres(in hundreds)
n. cycles
OK
0000
+/-
- +
No radio control
devices memorised
00
n. remotes
OK
+/-
- +
List of last 30 errors
01.33
err
OK
02.01
........
30.15
+/-
0---
password
ACCESS MENUS Fig. 1
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
Diagnostics
code
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHCL
PHOT CL closing photocell input activated
BAR
BAR safety edge input activated
SWC1
SWC1 motor 1 closing limit switch input activated
SWO1
SWO1 motor 1 opening limit switch input activated
SWC2
SWC2 motor 2 closing limit switch input activated
SWO2
SWO2 motor 2 opening limit switch input activated
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
ER01
ER02
Safety edge test failed
ER03
Opening photocell test failed
ER04
Closing photocell test failed
er06
8k2 safety edge test failed
ER1x
Board hardware test error
*
ER2x
Encoder error
*
ER3x
*
Reverse due to obstacle - Amperostop
Thermal cutout
ER4x
*
Communication error with remote devices
ER5x
*
ER7x
*
Internal system supervision control error.
Ersw
Error during limit switch adjustment
*X= 0, 1, .., 9, A, B, C, D, E, F
150-
10--
35. 4 0
DESCRIPTION
1520
prg
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or param-
eter/logic settings
-
C h e c k
c o n n e c t i o n s
t o
m o t o r
- Hardware problems with board (contact
technical assistance)
-
M o t o r p o w e r o r e n c o d e r s i g -
n a l c a b l e s i n v e r t e d / d i s c o n n e c t e d .
- Actuator movement is too slow or stopped
with respect to programmed operation.
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected
accessory devices and/or expansion boards
Try switching the board off and back on again.
If the problem persists, contact the technical
assistance department.
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both
the opening and closing limit switches.
- Caution: the last centimetre of the piston's stroke,
during either opening or closing, cannot be used.
THALIA
29