BFT THALIA Instructions D'installation page 35

Table des Matières

Publicité

Logic
Definition
HOLD-TO-RUN
Deadman
Block pulses during
IBL OPEN
opening
Block pulses during
|IBL TCA
TCA
Block pulses during
IBL CLOSE
closing
Hammer during
RAM BLOW C. O P
opening
Hammer during
RAM BLOW C. C L
closing
BLOC PERSIST
Stop maintenance
Closing limit switch
PRESS SWC
pressure
ICE
Ice feature
1 MOT. O N
1 motor active
OPEN IN OTHER
Open in other
direction
DIRECT.
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
0
 
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
2
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the sole-
0
 
1
noid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid
0
 
1
lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on
in the direction of the stop for approx. 3 seconds. This operation is performed every hour.
0
 
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil
1
due to a drop in temperature during extended pauses, such as during the night, or due to internal
leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
0
limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position.
0
 
This function allows leaves to press against the mechanical stop without the Amperostop sensor
interpreting this as an obstacle.
1
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as
the mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the
closing limit switches to trip slightly earlier (Fig.G Ref.A).
0
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower
0
 
than the value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
1
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and
closing cycle.
0
Both motors active (2 leaves).
0
 
1
Only motor 1 active (1 leaf ).
0
Standard operating mode (See Fig.G Ref. C).
0
 
1
Opens in other direction to standard operating mode (See Fig. G Ref.D)
Optional extras
35
THALIA

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

U-link thalia pThalia

Table des Matières