INSTALLATION
Permanent Surface Mounting
Tubular stand mounting permanently attaches the unit to a
countertop or serving table. All wiring may be concealed within
one of the tubular stands.
Ensure safe and proper operation. Refer to the "Minimum
Clearance Requirements" listed in the INSTALLATION
section of this manual.
The aluminum, non adjustable tubular stands are available in 1"
(25 mm) increments from 14"–24" (356–610 mm).
NOTE: Tubular stands are not field retrofittable.
NOTE: If wiring is to be concealed, a 1" (25 mm) diameter hole
must be provided in the mounting surface centered
under the stand containing the wiring conduit.
Distance from end of unit to center of conduit hole.
Needed for 1" diameter hole cutout in mounting surface.
1-3/16"
(30 mm)
Countertop Conduit Hole Dimension
1. Position the unit upside-down on a flat surface.
NOTE: Units for this application are supplied with the conduit
attached to one side of the unit. Conduit should not be
removed.
2. If applicable, route the flexible conduit through the center
of one of the stands.
3. Pull the conduit-side stand up against the unit and secure
the stand to the unit using the screws supplied.
4. Align the other stand with the mounting holes at the
opposite end of the unit and secure the stand to the unit
using the screws supplied.
5. If applicable, route the flexible conduit through the 1"
(25 mm) diameter hole cut into the mounting surface.
6. Secure the stands to the mounting surface.
NOTE: Two pairs of stands will be needed for mounting dual
units.