INSTALLATION
Conduit Connection
Units supplied with a right angle
fitting and flexible conduit attached
have had all internal connections
completed at the factory. Attach the
proper power supply leads to the
high temperature lead wires in the
conduit.
NOTE: Refer to the wiring diagram
supplied with the unit and specifications label attached
to the unit for specific electrical information.
Remote Control Enclosures
Hatco Remote Control Enclosures (RMBs) include switches,
wire leads, and/or indicator lights and are ready for installation.
Proper use of RMBs require one RMB per strip heater.
NOTE: Remote control enclosures are available in several
sizes. All models are built in accordance with UL
standards to accommodate switches, indicator lights,
and wiring, ready for installation. See the OPTIONS
section near the back of this manual.
IMPORTANT NOTE:
Remote mounted enclosures and control switches must be
installed in a cool, dry location as far away from any heat zone
as possible. Do not mount enclosures or switches directly on,
under, or above unit. Do not mount enclosures or switches
in direct contact with any heated surface or near any steam
generating equipment.
Remote Mounted Control Switches
Optional remote mounted control switches include I/O (on/off)
toggle switches and infinite control switches. These switches
need to be installed into an approved electrical box/enclosure
(not supplied) by a qualified electrician. See the OPTIONS AND
ACCESSORIES section for more information.
Fitting
NOTE: When two or more units are mounted where the heat
Conduit
Remote mounted control boxes must be installed outside
strip heater heat zone to prevent premature failure of
components due to excessive heat.
Remote Mounted Enclosure Installation Locations
20
from one housing tends to raise the temperature of
another, the control switches should be installed in a
remote control enclosure. Units in a multiple installation
should use remote mounted control switches.
NOTICE
Heat
Mounting
Mounting
Screw
Flange
English
Form No. UGAM-0718