Undershelf Mounting - Hatco Ultra-Glo Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Undershelf Mounting

Undershelf mounting permanently attaches the unit to the
underside of a shelf. It can be mounted to a flat shelf or a shelf
with rolled/flanged edges using the included adjustable angle
brackets. A minimum gap of 1" (25 mm) is required between the
unit and the underside of the shelf to prevent heat damage to
the electrical system of the unit.
Ensure safe and proper operation. Refer to the "Minimum
Clearance Requirements" listed in the INSTALLATION
section of this manual.
NOTE: When mounting the unit under a shelf, it is recommended
to use a remote control enclosure.
If the shelf has a rolled or flanged edge, use the appropriate
screw hole locations on the adjustable angle brackets to mount
the unit below the lowest edge of the rolled or flanged shelf.
The adjustable angle brackets can provide a 1" (25 mm),
1-1/2" (38 mm), or 2" (51 mm) gap between the unit and the
underside of the shelf.
NOTICE
DO NOT conceal unit. Unit must be installed below lowest
edge of a rolled or flanged shelf. Failure to mount unit
properly may result in premature failure of switches and
void the product warranty.
Shelf with 3/4" (19 mm)
flanged edge
Adjustable
Angle
Bracket
Flanged Shelf Installation
Form No. UGAM-0718
CAUTION
1" (25 mm)
Gap
Minimum
Unit below
lowest edge of
flanged shelf.
Adjustable Angle Bracket Mounting
1. Position the unit on a flat surface with the heating elements
facing down.
2. Remove the two middle screws from each end of the unit.
3. Align the appropriate holes on an adjustable angle bracket
with the middle screw holes on one end of the unit. Secure
the angle bracket using the removed middle screws.
4. Repeat step 3 for the opposite end of the unit.
Middle
Screws
Adjustable
Angle Bracket
Adjustable Angle Bracket Installation
5. Fasten the angle brackets to the underside of the shelf
using appropriate fasteners (not supplied by Hatco).
NOTE: Two pairs of brackets will be needed for dual units.
Two adjustable
angle brackets
on each end
for dual units.
Dual Unit Mounting
17