Overhead Mounting; Electrical Information - Hatco Ultra-Glo Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Overhead Mounting

Overhead hanger post mounting permanently attaches the unit
to an overhead surface. All wiring may be concealed within one
of the hanger posts. Overhead mounting is for single element
depth units.
WARNING
Ensure safe and proper operation. Refer to the "Minimum
Clearance Requirements" listed in the INSTALLATION
section of this manual.
Hanger posts are available in aluminum non-adjustable lengths
from 3"– 10" (76 – 254 mm).
NOTE: Hanger posts are not field retrofittable.
NOTE: If wiring is to be concealed, a 1" (25 mm) diameter hole
must be provided in the mounting surface centered
above the hanger post containing the wiring conduit.
1. Make sure the overhead mounting surface is secure and
will allow the unit to be suspended at a level, safe, and
proper distance from walls, counter, and food.
2. Position the unit on a flat surface with the heating elements
facing down.
NOTE: Units for this application are supplied with the conduit
attached to one side of the unit. Conduit should not be
removed.
3. If applicable, route the flexible conduit through the center
of one of the hanger posts.
4. Pull the conduit-side hanger post down onto the unit and
secure the post to the unit using the screws supplied.
5. Align the other hanger post with the mounting holes at the
opposite end of the unit and secure the post to the unit
using the screws supplied.
6. If applicable, route the flexible conduit through the 1"
(25 mm) diameter hole cut into the mounting surface.
7. Carefully lift the unit and secure the hanger posts to the
overhead mounting surface.
NOTE: Two pairs of hanger posts will be needed for mounting
dual units.
Form No. UGAM-0718
Hanger Post Mounting

Electrical Information

Refer to the wiring diagram supplied with the unit and
specification label attached to the unit for specific electrical
information. Also, refer to the "Electrical Rating Charts" in the
SPECIFICATIONS section for unit specific information.
ELECTRIC SHOCK HAZARD: Unit must be installed by a
qualified electrician. Installation must conform to all local
electrical codes. Installation by unqualified personnel will
void unit warranty and may lead to electric shock or burn,
as well as damage to unit and/or its surroundings.
NOTE: If the unit being installed is not shown or listed in this
manual, refer to the wiring diagram supplied with the
unit and the installation information on the unit for
further instructions.
Power Supply
Install supply wire and connectors suitable for at least 194°F
(90°C).
• Use a minimum of No. 14 AWG copper wire for individual
circuits up to 15 amps.
• Use a minimum of No. 12 AWG copper wire for individual
circuits 15 to 20 amps.
• Use a minimum of No. 10 AWG copper wire for individual
circuits 20 to 25 amps.
NOTE: Refer to the wiring diagram supplied with the unit and
specifications label attached to the unit for specific
electrical information.
19
INSTALLATION
Flexible
Conduit
Hanger Post
Mounting Screw
WARNING