Installing Chain Suspended Units; Installing Permanent Units; Tubular Stand Mounting - Hatco GLO-RAY GR Serie Manuel D'installation Et D'utilisation

Rampes chauffantes à infrarouge
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

Installing Chain Suspended Units

Chain suspension mounting attaches a strip heater to an
overhead surface with the use of "S" hooks.
NOTE: Units ordered with the "S" hook option come with two
"S" hooks and two 6" (152 mm) pieces of connecting
chain. Additional chain (P/N 05.03.020.00) can be
ordered from Hatco for the overhead mounting system
or another option can be determined by a qualified
installer.
WARNING
For installation with chains, make sure the chains have
sufficient strength and are securely fastened to both the
unit and the mounting location. Poorly installed chains may
cause the unit to loosen and fall. Do not place anything on
top of units installed with chains.
To ensure safe and proper operation, refer to the Clearance
Requirements listed in the Installation section of this
manual.
NOTE: The strength of the chain supplied by Hatco is sufficient
to hold the weight of the unit securely only when
mounted properly.
1. Prepare the overhead mounting system for the "S" hooks.
make sure the system is secure and is set up so the unit
will be suspended at a level, safe, and proper distance from
walls, counter, and food.
2. Loosen, but do not remove the screws securing the hanger
tabs on each end of the unit. Rotate the tabs up, then
tighten the screws securely.
3. Securely attach one of the 6" (152 mm) connecting chains
between each pair of hanger tabs.
4. attach an "S" hook to the center of each connecting chain.
5. Carefully lift the unit and attach the "S" hooks on each end
of the unit to the overhead mounting system. make sure
the unit is level.
Overhead Mounting
System
"S" Hook mounting
"S" Hook
Connecting Chain
Hanger Tab
Screw

Installing Permanent Units

Strip heaters can be mounted permanently with tubular stands
or angle brackets. Permanent units are not available with a
power cord and plug connection. Refer to the proper permanent
mounting section for the installation procedure.

Tubular Stand Mounting

Tubular stand mounting permanently attaches the unit to a
countertop or serving table. all wiring may be concealed within
one of the tubular stands.
To ensure safe and proper operation, refer to the Clearance
Requirements listed in the INSTALLATION section of this
manual.
Non-adjustable tubular stands are available in aluminum,
Designer colors, or gloss finishes in heights from 10"–16"
(254–406 mm). adjustable tubular stands are available in
stainless steel in heights from 10"–14" (254–356 mm).
NOTE: Tubular stands are not field retrofittable.
NOTE: If wiring is to be concealed, a 1" (25 mm) diameter hole
must be provided in the mounting surface under the
stand containing the wiring conduit.
1. Position the unit upside-down on a flat surface.
NOTE: Units for this application are supplied with the conduit
attached to one side of the unit. Conduit should not be
removed.
2. If applicable, prepare the mounting surface for concealing
wiring.
a. Cut a 1" (25 mm) diameter hole into the mounting
surface at the appropriate location.
NOTE: The distance between the center of the two stands is
found by subtracting 2-7/16" (62 mm) from the overall
width of the strip heater.
b. Route the flexible conduit through the tubular stand and
into the mounting surface.
1-3/16"
(30 mm)
Mounting Hole Distance =
Width (A) – 2-7/16" (62 mm)
Countertop Conduit Hole Dimension
10
English
CAUTION
A
Form No. GRm-0115

Publicité

Chapitres

Table des Matières
loading

Table des Matières