b0 1. Unité de
2. Activation fonction de
mesure du
sauvegarde (uniquement
paramètre b1
pour le branchement des
M = minutes ;
unités en réseau)
H = heures
186
H
OFF
187
H
OFF
188
H
OFF
189
H
OFF
190
H
OFF
191
H
OFF
192
H
ON
193
H
ON
194
H
ON
195
H
ON
196
H
ON
197
H
ON
198
H
ON
199
H
ON
200
H
ON
201
H
ON
202
H
ON
203
H
ON
204
H
ON
205
H
ON
206
H
ON
207
H
ON
208
H
ON
209
H
ON
210
H
ON
211
H
ON
212
H
ON
213
H
ON
214
H
ON
215
H
ON
216
H
ON
217
H
ON
218
H
ON
219
H
ON
220
H
ON
221
H
ON
222
H
ON
223
H
ON
224
H
ON
225
H
ON
226
H
ON
227
H
ON
228
H
ON
229
H
ON
230
H
ON
231
H
ON
232
H
ON
233
H
ON
234
H
ON
235
H
ON
236
H
ON
237
H
ON
238
H
ON
239
H
ON
240
H
ON
241
H
ON
242
H
ON
243
H
ON
244
H
ON
245
H
ON
246
H
ON
247
H
ON
248
H
ON
249
H
ON
250
H
ON
251
H
ON
252
H
ON
253
H
ON
254
H
ON
255
H
ON
7.3 Paramètres de branchement série
Paramètre
C1
débit en bauds : 0 = 4800 bps ; 1 = 9600 bps ; 2 = 19200 bps ; 3 =
38400 bps
C2
Adresse tLan (si 0 = maître)
C3
adresse série
C4
Délai pour la génération d'alarme déconnectée maître série
7.4 Paramètres de lecture seule
Paramètre
d0
lecture de la température de la sonde TH
d1
lecture de l'humidité de la sonde TH
d2
lecture entrée configurable (carte en option)
d3
compteur heures fonctionnement cuve (remise à zéro, voir 5.5)
d4
compteur heures de la machine (lecture seule)
d5
Production instantanée
d6
Temps restant fin de vie transducteurs
(*) après 999 l'écran affiche
pour indiquer 1 000 (trois chiffres sont indiquées avec un point en haut entre le premier et le deuxième chiffre).
Direct version for room applic. +0300062FD - rel. 1.1 - 16.11.2017
3. Électrovanne
4. Activation relais alarme
d'évacuation en
AL= présence alarmes
veille
SP= point de consigne
atteint
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
AL
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Open
SP
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
AL
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
Closed
SP
UM
UOM
°C/°F
%rH
% / %rH
kg/h
20
5. Logique relais alarme
6. Activation
NO= norm. ouvert
lavage pour
NC= norm. fermé
inactivité
NC
On
NC
On
NC
Off
NC
Off
NC
On
NC
On
NO
Off
NO
Off
NO
On
NO
On
NO
Off
NO
Off
NO
On
NO
On
NC
Off
NC
Off
NC
On
NC
On
NC
Off
NC
Off
NC
On
NC
On
NO
Off
NO
Off
NO
On
NO
On
NO
Off
NO
Off
NO
On
NO
On
NC
Off
NC
Off
NC
On
NC
On
NC
Off
NC
Off
NC
On
NC
On
NO
Off
NO
Off
NO
On
NO
On
NO
Off
NO
Off
NO
On
NO
On
NC
Off
NC
Off
NC
On
NC
On
NC
Off
NC
Off
NC
On
NC
On
NO
Off
NO
Off
NO
On
NO
On
NO
Off
NO
Off
NO
On
NO
On
NC
Off
NC
Off
NC
On
NC
On
NC
Off
NC
Off
NC
On
NC
On
plage
déf.
-
0...3
2
-
1...207
1
s
0...240
30
L'alarme n'est générée que si le contrôle de la
production via réseau est actif (voir chap. 12.2).
plage
déf.
0-1000
0
0-1000
0
0-100
0
h
0-9999(*)
0
h
0-9999(*)
0
0...8
0
h
0...9999(*)
9999
Pari a AF-d3
7. Off = lavage pour inactivité
8. Auto-test
au prochain démarrage
On = lavage pour inactivité
effectué régulièrement
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
On
Off
On
On
On
Off
On
On
Tab. 7.b