Télécharger Imprimer la page

Erreka VIVO-M203 Guide Rapide D'installation Et Programmation page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

D1 D2 Parameter
A
0
Flashing light
1
Garage light time
2
Torque/nominal force
3
Regulation of torque/force and
slowdown speed
5
Recede after closing (ensures the
o pe ra to r d o e s n o t b e c o m e
seized on the stopper)
6
Torque/maximum trapping force
(level of increase relative to
nominal)
The D3 digit allows the level to
be adjusted during opening;
The D4 digit allows the level to
be adjusted during closing
7
(Opening or closing) photocell
u s e d d u r i n g s t a n d b y ( i n
automatic mode only)
8
E f f e c t
o f
pushbuttons during standby (in
automatic mode only)
9
Opening mode
A
L a p s e b e t w e e n l e a v e s i n
opening and closing
b
Use of the EPS1 card connector
For parameters Ab02 and Ab03,
use the EPS1 card and bridge the
network input cable connectors
instead of connecting them to
t h e n e t w o r k ( s e e " B r a k e
connection" diagram).
C
Hydraulic pressure maintenance
d
Ram
E
Special features
N
0
Programming lock key
Be sure to remember any key
used, for future access to the
programming
1
Total operations completed
2
Partial operations completed
t
0
FTP communication
1
GSM signal intensity
Complete programming chart (and II)
D3
0
0..5. 0...9
0
0
0
0...9 0...9
0
0
t h e
S T 1 - S T 2
0
0...9 0...9
0
0
0
0
0
X
X
O
X
Default
D4
Options or values
option
1, 2
01
01: output with voltage, with no pre-warning
02: output with voltage, with pre-warning
03
03 = 3 sec.; 59 = 59 sec.; 2.5 = 2 min. 50 sec.;
....; maximum 4 minutes
1...9
09
01: minimum,..., 09: maximum
1...9
09
01: minimum,..., 09: maximum
0...5
00
00: no recede; ...;
05: maximum recede
00
00: disabled in opening and closing;
01: disabled in opening and level 1 in closing;
10: level 1 in opening and disabled in closing;
....;
65: level 6 in opening and level 5 in closing;
...;
99: level 9 in opening and closing
0...2
02
00: does not affect standby time
01: immediate close when the photocells are
02: restarts standby time
0...2
02
00: has no effect during standby
01: brings about closing after 3 seconds
02: restart standby time
1...3
02
01: community opening
02: step-by-step alternative shutdown
03: automatic alternative shutdown (if F200 is
22
00: no lapse in opening or closing (only apply in
XY: X lapse in opening
0...3
00
00: use for standard traffic light;
01: use for brakes
02: NC contact with gate open (L1-COM) and
03: impulse 1 second Open (L1-COM) when
0...6
00
00: no pressure maintenance;
01: every 0.5 hours;
03: every 2 hours;
05: every 12 hours;
0,1
00
00: no ram;
0...2
00
00: no special function;
01: opening photocell C4 programmed for
02: industrial;
0,1
0000
The preset option is 0000 (no key). If any figure is
changed, this is considered a key.
Select the required key (starting with D1) using
UP and DOWN. Press ESC to cancel or ENTER to
confirm and move to D2, and so on.
X
Indicates the hundreds of cycles completed (for
example, 68 indicates 6,800 cycles completed)
X
Indicates the hundreds of cycles completed. This
can be reset by pressing ST1, ST2 and ENTER at
the same time.
ç
Immediate communication with the server
X
Indicates signal intensity
released
selected, A903 changes to A902)
gates without overlap);
(X=1: 1 second, ... , X=9: 9 seconds)
Y lapse in closing
(Y=1: 1 second, ... , Y=9: 9 seconds)
gate closed (L2-COM)
starting opening and Close (L2-COM) when
starting closing. Allows another board to be
activated.
02: every 1 hour;
04: every 6 hours;
06: every 24 hours
01: with ram
pedestrian passage;
16

Publicité

loading

Ce manuel est également adapté pour:

Vivo-m203m