COMMISSIONING FOR
INITIAL START-UP
When commissioning the ap-
pliance and when starting it after
a prolonged stop, it must be tho-
roughly cleaned to eliminate all resi-
due of extraneous material (see chap-
ter 3 / Removal of protective materials).
DAILY ACTIVATION
Check the cleanliness and hygiene
1.
of the appliance.
Make sure that the room exhaust sy-
2.
stem works properly.
When necessary, plug the appliance
3.
into the appropriate socket.
Open the network locks upstre-
4.
am the appliance (Gas - Water -
Electric).
Make sure that the water drain (if
5.
present) is not clogged.
Proceed with the operations described
in "Starting production".
In order to free air in the pipes,
open the network lock, turn the
knob of the appliance while pres-
sing it in the piezoelectric position, pla-
ce a flame (match or the likes) on the
pilot light and wait for it to ignite.
DAILY DECOMMISSIONG / Upon
completion of the operations descri-
bed above:
1. Close the network locks upstream the
appliance (Water - Gas - Electric).
UPSTREAM DYNAMIC
PRESSURE CONTROL / See gas in-
let pressure detection.
INJECTOR PRESSURE
CONTROL
If the measured pressure is lower
than the 20% compared to the en-
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
OPERATIONS FOR COMMISSIONING
2. Make sure that the drain cocks (if
present) are "Closed".
3. Check the cleanliness and hygiene
of the appliance.
PROLONGED DECOMMISSIONING
/ In case of prolonged inactivity, per-
form all the procedures described
for daily putting out of service and
protect the parts most exposed to
oxidation as indicated below:1. Use
lukewarm water with a bit of soap to
clean the parts;
2. Rinse the parts thoroughly, wi-
thout using pressurised and/or direct
water jets;
3. Dry the surfaces carefully using
non-abrasive material;
4. Wipe a non-abrasive cloth lightly
soaked with food-safe Vaseline oil
over all of the stainless steel surfaces
in order to create a protective film.
For appliances with doors and rub-
ber gaskets, leave the door slightly
ajar to let it air out and spread pro-
tective talcum powder on the rubber
gasket surfaces.
Periodically air the appliances and
rooms.
a year by an authorized technician of
the assistance service.
GAS TYPE CHANGEOVER
try pressure, suspend the installation
and contact the authorized customer
care service
the installation and contact the authori-
zed customer care service
- 15 -
To make sure that the appliance
is in perfect technical conditions,
arrange for service at least once
If the measured pressure is higher
than the entry pressure, suspend
5.
EN
6.