Internal wiring only
240 V SINGLE PHASE HEATER
KIP-30-W1 / KIP-45-W1 / KIP60-W1 / KIP-80-W1
HEATING
ELEMENTS
1
CONTACTOR
1 2
3 4
5
L1 A1 L2 A2
CG170-U1/CX170-U1
CONTROL
Figure 6. Wiring diagram
SAUNA HEATER (240 V) WITH CONTROL UNIT
Model
kW
Amps
KIP-30-W1
3.0
12.5
KIP-45-W1
4.5
18.8
KIP-60-W1
6.0
25.0
KIP-80-W1
8.0
33.3
SAUNA HEATER (208 V) WITH CONTROL UNIT CG170-U3/CX170-U3
Model
kW
KIP-30-W3
3.0
KIP-45-W3
4.5
KIP-60-W3
6.0
KIP-80-W3
8.0
Internal wiring only
240 V SINGLE PHASE HEATER
KIP-80-W1
2
1
3
LIMIT
CONTROL
1 2
GROUND
GND
L1 A1 L2 A2
CG170-U1-15/CX170-U1-15
Voltage
Phase
Wire size Control
240
1
12
240
1
10
240
1
10
240
1
8
Amps
Voltage
Phase
8.3
208
3
12.5
208
3
16.7
208
3
22.2
208
3
2
3
3 4
5
GND
CG170-U1/CX170-U1
CG170-U1/CX170-U1
CG170-U1/CX170-U1
CG170-U1-15/CX170-U1-15
Wire size
14
14
12
10
Internal wiring only
208 V 3 PHASE HEATER
KIP-30-W3 / KIP-45-W3 / KIP-60-W3 / KIP-80-W3
1
2 3 4
5
L1 A1 L2
A2
L3
GND
CG170-U3/CX170-U3
7