Connection and operation
Warning
Read warning notice and
instruction manual carefully
prior to initial operation
and save the information
for later use.
Permissible installation
Mains connection
Connect the machine to the correct mains supply.
Please read the type plate (U
machine.
0
l
1
Important!
In order to avoid destruction
of plugs and cables, good
electric contact is required when
connecting earth cables and
welding hoses to the machine.
Connection of shielding gas
Connect the gas hose, which branches off from the
back panel of the welding machine (2), to a gas supply
with pressure regulator (2-6 bar). (Note: Some types
of pressure regulators require an output pressure of
more than 2 bar to function optimally).
Press the torch gas hose into the gas connecting
branch (6) at the front of the machine.
Connection of electrode holder for MMA
The electrode holder and return current cable are
connected to plus tap (4) and minus tap (5). Observe
the instructions from the electrode supplier when
selecting polarity.
) on the rear side of the
1
2
5
7
4
6
1.
Mains connection
2.
Gas hose
3.
Power switch
4.
Connection of earth clamp (TIG) or electrode holder (MMA)
5.
Connection of TIG welding hose or earth clamp (MMA)
6.
Connection of shielding gas - TIG welding hose
7.
Connection of foot control
Switch on, press, weld
Welding program setting
•
Switch on the welding machine on the main switch (3)
•
Select process
See Quickguide
•
Adjust welding current and
secondary parameters.
For more information about
setting the parameters, please
refer to the quick guide
•
The machine is ready to weld
WARNING
Voltage is present on the welding
wire/electrode when pressing the
welding hose trigger.
7
1
Power
F
N
A
V
t
t
S
1
2
%
V
FOCUS TIG 200 AC/DC
PFC
A
QUICKGUIDE
FOCUS TIG 200
PFC
UK
2
3
Gas