3. Technical data

The values stated in the technical data must be
Caution
adhered to.

3.1 General data

3.1.1 Materials, weight, temperatures
Materials
Approx. weight [kg]
Temperature for operation, transport and
storage [°C]
Major temperature fluctuations during operation can
Caution
cause condensation in the product, which may lead
to malfunction in the long term.
3.1.2 Flow rate Cl
, SO
2
2
Maximum flow rate
Minimum flow rate
*
Pounds per day
3.1.3 Connections
Capacity
Inlet / outlet connection
[kg/h]
[mm]
4
PE 8/11
4
1/2" USA
10
PE 10/14
10
PVC 12/16 (DN 10)
10
PE 12/16
10
PVC 15/20 (DN 15)
10
1/2" USA
* Between product enclosure and connection

3.2 Optional remote indication

Change-over device 189 with two reed
Variant
contacts for remote indication
Max. supply voltage
75 / 50
[VDC / VAC]
Power
1
consumption [A]
Max. wattage [W]
50
6

3.3 Dimensions

PVC
FKM
FEP
Glass
Silver
®
Hastelloy
C
2
0-40
10 kg/h
500 PPD*
≥ 50 g/h
≥ 2.5 PPD*
Gasket*
O-ring
PTFE tape
O-ring
O-ring
PTFE tape
O-ring
PTFE tape
Fig. 2
Dimensions in mm (inch)