3.3 Operation the engine

3.3.1 Starting the engine
Turn the fuel valve (1) to «ON»
OFF
ON
1
Push the choke lever (2) to «CLOSE»
CLOSE
B6899004.cdr
Set throttle lever (3) to full throttle
max
3
B6899002.cdr
2
min
B6899003.cdr
Set the engine switch (4) to «ON»
OFF
ON
Honda GX 100_05
Pull the starter handle (5) slightly until resistance is
noticeable, then pull firmly
5
Honda GX 100_06
Do not allow the starter handle (5) to spring back
against the engine. Move the starting cable back
into its initial position manually to prevent the
Attention
starter being damaged.
Do not use the choke when the engine is warm or
at high outside tempertures.
After the engine has started:
Set the throtte lever to idling
Allow the engine to warm up for 1 to 2 minutes
Set the choke lever (2) during the warming up phase to
«OPEN»
3.3.2 Switching off the engine
Set the throttle lever (3) to «min.»
Turn the engine switch (4) to «OFF»
Set the fuel valve (1) to «OFF»
In case of emergencies, the engine switch should be
turned to «OFF» to switch off the engine.
Important