3.3 Operation the engine
3.3.1 Starting the engine
•
Turn the fuel valve (1) to «ON»
OFF
Honda GX 100_14
•
Push the choke lever (2) to «CLOSE»
2
OPEN
Honda GX 100_03
•
Set throttle lever (3) to full throttle
Honda GX 100_04
1
ON
CLOSE
CLOSE
min
max
3
•
Set the engine switch (4) to «ON»
OFF
ON
Honda GX 100_05
•
Pull the starter handle (5) slightly until resistance is
noticeable, then pull firmly
5
Honda GX 100_06
Do not allow the starter handle (5) to spring back
against the engine. Move the starting cable back
into its initial position manually to prevent the
Attention
starter being damaged.
Do not use the choke when the engine is warm or
at high outside tempertures.
After the engine has started:
•
Set the throtte lever to idling
min
•
Allow the engine to warm up for 1 to 2 minutes
•
Set the choke lever (2) during the warming up phase to
«OPEN»
3.3.2 Switching off the engine
•
Set the throttle lever (3) to «min.»
max
•
Turn the engine switch (4) to «OFF»
•
Set the fuel valve (1) to «OFF»
In case of emergencies, the engine switch should be
turned to «OFF» to switch off the engine.
Important
25
3. Operation
OFF
ON
4