• CONNECT 5 - automaton mode :
This mode enables to pilot the machine from a console or from an automaton using the 5 pre-saved programs.
For the foot pedal, the «Switch (D)» enables to start or stop welding according to the chosen cycle. The voltage value for the «slider (B)» matches
a program or the actual status.
The voltage must be between 0 and 10.0V by step of 1.6V matching program reminder :
- Current context : 0 – 1.6 V
- Program 1 : 1.7 – 3.3 V
- Program 2 : 3.4 – 5.0 V
- Program 3 : 5.1 – 6.6 V
- Program 4 : 6.7 – 8.3 V
- Program 5 : 8.4 – 10.0 V
An additional potentiometer enables to change the current (+/- 15%) either whilst welding or not.
The information ARC ON (arc presence) enables the automaton to synchronise itself (Pull Up 100k entry, automaton side).
Put the pin AUTO_DETECT to the earth enables to start the product without going through the selection window where you can select the type of
remote control used.
The 5 loaded settings correspond to the first 5 saved programs (P1 to P5).
The signals' I/O (input/output) are protected at 6.1V.
Additional explanations are available on our website (https://goo.gl/i146Ma).
COOLING FAN
To minimise sound and dust aspiration, the station integrates a controlled fan system. The fan's rotation speed depends on the temperature and the
machine's settings.
ACCESS TO SETUP MENU
or
x 3s
or
Present
value
Present
value
Energy menu
QMOS/DMOS
36
x 3s
Release of the buttons or scrollwheel
Advance menu of the process
Exit the advance menu
Present
value
Present
value
Present
value
TITAN 400 DC
Short-circuit of the cables and validation. Display
Calibration
value
2s and exit of the menu.
1s
1s
1s
Validation of the state of the
cooling unit and exit of the menu.
Validation of the tolerance value
and exit of the menu.
Validation of the display in
I/U or Energy of the Hold
mode.
Validation of the applica-
tion of thermal coefficient
when calculating the
energy.
Validation of the applica-
tion of the length of the
weld.
Reset all Manufacturer settings for all processes and
exit the menu.